{"id":897,"date":"2015-11-21T13:56:04","date_gmt":"2015-11-21T19:56:04","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=897"},"modified":"2022-10-15T16:03:59","modified_gmt":"2022-10-15T22:03:59","slug":"what-is-revenue-grade-accurate-flow-metering-telemetry","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=897","title":{"rendered":"What is Revenue-Grade-Accurate Flow Metering?"},"content":{"rendered":"<hr \/>\n<hr \/>\n<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n<p>Telemetry, SCADA, and Building Automation System Integrators have wrestled for decades\u00a0with totalization errors associated with pulse-output flow meters.<\/p>\n<p>The EtherMeter was designed to <em><strong>eliminate<\/strong><\/em> these errors.\u00a0 We call the result: <em><strong>Revenue-Grade-Accurate Flow Metering<\/strong><\/em>.<\/p>\n<p>By leveraging absolute-encoder AMR technology &#8212; which is offered as a low-cost\u00a0option by all of the major AWWA-type\u00a0water meter manufacturers &#8212; the EtherMeter ensures that the connected automation system is collecting\u00a0meter totalization data that is an exact match to the reading on the meter itself. \u00a0And because there is zero totalization error, the numbers presented in the automation system can be used with confidence for EPA reports, revenue billing, and other record keeping\u00a0where error-free accuracy is required.<\/p>\n<p>Prior to the EtherMeter&#8217;s revenue-grade SCADA metering solution, utilities were often forced to resort to manual meter reads to fill out their official SCADA\/Telemetry reports. \u00a0And because many flow meters are installed at remote locations and\/or within confined spaces, manual reading can occur at considerable cost and inconvenience.<\/p>\n<p>The photos below illustrate a typical SCADA flow metering application within a Rural Water District pumping station that was originally commissioned in May 2012.\u00a0 Had this station been equipped with pulse-counting instrumentation rather than an EtherMeter,\u00a0by the time of this writing &#8212; after 435,210,100 gallons having passed through the station &#8212; there would most likely be a significant difference between the SCADA system meter reading and the reading displayed on the meter.<\/p>\n<p>With the EtherMeter-based solution, it is noteworthy &#8212; and illustrated in the photos &#8212; that\u00a0the SCADA System has access to the exact reading as displayed on the meter register.<\/p>\n<div id=\"attachment_900\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Pump_and_Meter.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-900\" class=\"size-medium wp-image-900\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Pump_and_Meter-300x225.jpg\" alt=\"Triplex Pumping Station - Jersey County Rural Water District (IL). Three (3) 60 HP Pumps and One (1) Sensus 6 Inch Omni-T2 Flow Meter. \" width=\"300\" height=\"225\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Pump_and_Meter-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Pump_and_Meter-1024x768.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Pump_and_Meter.jpg 1077w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-900\" class=\"wp-caption-text\">Triplex Pumping Station &#8211; Jersey County Rural Water District (IL). Three (3) 60 HP Pumps and One (1) Sensus 6 Inch Omni-T2 Flow Meter. (Click to Zoom)<\/p><\/div>\n<div id=\"attachment_902\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Sensus_Omni_T2_6_Inch_Closeup.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-902\" class=\"size-medium wp-image-902\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Sensus_Omni_T2_6_Inch_Closeup-300x225.jpg\" alt=\"Sensus 6 Inch Omni-T2 Flow Meter.\" width=\"300\" height=\"225\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Sensus_Omni_T2_6_Inch_Closeup-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Sensus_Omni_T2_6_Inch_Closeup-1024x768.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Sensus_Omni_T2_6_Inch_Closeup.jpg 1077w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-902\" class=\"wp-caption-text\">Sensus 6 Inch Omni-T2 Flow Meter. \u00a0The Sensus Omni-series meters offer both encoder and pulse signaling. \u00a0It is important to note that the EtherMeter is reading totalization and flow rate from the encoder signal and ignoring the pulse signal. (Click to Zoom.)<\/p><\/div>\n<div id=\"attachment_903\" style=\"width: 235px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Control_Panel.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-903\" class=\"size-medium wp-image-903\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Control_Panel-225x300.jpg\" alt=\"Telemetry\/SCADA Control Panel. Note the EtherMeter Installed Within the Panel. Communication Between PLC and EtherMeter: Modbus\/RTU over RS-485.\" width=\"225\" height=\"300\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Control_Panel-225x300.jpg 225w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Control_Panel-768x1024.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Control_Panel.jpg 808w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/a><p id=\"caption-attachment-903\" class=\"wp-caption-text\">Telemetry\/SCADA Control Panel. Note the EtherMeter Installed Within the Panel.\u00a0 Available Communication Methods Between the\u00a0EtherMeter and the PLC:\u00a0Modbus\/RTU, Modbus\/ASCII,\u00a0Modbus\/TCP, DF1, and EtherNet\/IP. Available Communication Ports on the EtherMeter: 10-BaseT Ethernet, RS-485, RS-232. (Click to Zoom.)<\/p><\/div>\n<div id=\"attachment_901\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Register_Match.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-901\" class=\"size-medium wp-image-901\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Register_Match-300x225.jpg\" alt=\"Closeup of the Sensus Meter Register. Note the Reading: 435210100 Gallons.\" width=\"300\" height=\"225\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Register_Match-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Register_Match-1024x768.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/Register_Match.jpg 1077w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-901\" class=\"wp-caption-text\">Closeup of the Sensus Meter Register. Note the Reading: 435210100 Gallons. (Click to Zoom.)<\/p><\/div>\n<div id=\"attachment_905\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/EtherMeter_Totalization_Match.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-905\" class=\"size-medium wp-image-905\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/EtherMeter_Totalization_Match-300x225.jpg\" alt=\"Closeup of the EtherMeter. Note the Exact Match to the Meter Register: 435210100 Gallons.\" width=\"300\" height=\"225\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/EtherMeter_Totalization_Match-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/EtherMeter_Totalization_Match-1024x768.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/EtherMeter_Totalization_Match.jpg 1077w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-905\" class=\"wp-caption-text\">Closeup of the EtherMeter. Note the Exact Match to the Meter Register: 435210100 Gallons. (Click to Zoom.)<\/p><\/div>\n<div id=\"attachment_904\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/EtherMeter_FlowRate.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-904\" class=\"size-medium wp-image-904\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/EtherMeter_FlowRate-300x225.jpg\" alt=\"The EtherMeter Also Calculates and Reports Accurate Rate-of-Flow Data.\" width=\"300\" height=\"225\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/EtherMeter_FlowRate-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/EtherMeter_FlowRate-1024x768.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/11\/EtherMeter_FlowRate.jpg 1077w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-904\" class=\"wp-caption-text\">The EtherMeter Also Calculates and Reports Accurate Rate-of-Flow Data: \u00a0In this instance, +742.350 GPM (Click to Zoom.)<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Telemetry, SCADA, and Building Automation System Integrators have wrestled for decades\u00a0with totalization errors associated with pulse-output flow meters. The EtherMeter was designed to eliminate these errors.\u00a0 We call the result: Revenue-Grade-Accurate Flow Metering. By leveraging absolute-encoder AMR technology &#8212; which is offered as a low-cost\u00a0option by all of the major AWWA-type\u00a0water meter manufacturers &#8212; the <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=897\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":908,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,4,5,6],"tags":[135],"class_list":["post-897","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-meteringtechnology","category-modbusprotocol","category-rockwell-protocols","tag-revenue-grade-accuracy"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/897","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=897"}],"version-history":[{"count":25,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/897\/revisions"}],"predecessor-version":[{"id":2423,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/897\/revisions\/2423"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/908"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=897"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=897"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}