{"id":4299,"date":"2026-08-03T09:48:07","date_gmt":"2026-08-03T15:48:07","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=4299"},"modified":"2026-08-03T16:03:00","modified_gmt":"2026-08-03T22:03:00","slug":"splitting-a-pulse-signal-with-the-analog-pulse-kit","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=4299","title":{"rendered":"Splitting a Pulse Signal with the Analog\/Pulse Kit"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &apos;Slim&apos;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">James Mimlitz @ SCADAmetrics &#8211; &#8216;Slim&#8217;<\/p><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Many commercial and industrial flow meters feature a 2-wire, pulse-output that represents a <strong>volumetric total signal<\/strong> (eg: gallons).  For example:  1 pulse = 1 gallon, or 1 pulse = 10 gallons, etc&#8230; The volumetric pulse signal has historically been used by <strong>SCADA<\/strong> (<strong><span style=\"text-decoration: underline;\">S<\/span><\/strong>upervisory <strong><span style=\"text-decoration: underline;\">C<\/span><\/strong>ontrol <strong><span style=\"text-decoration: underline;\">a<\/span><\/strong>nd <strong><span style=\"text-decoration: underline;\">D<\/span><\/strong>ata <strong><span style=\"text-decoration: underline;\">A<\/span><\/strong>cquisition) systems to convey totalized flow.  Furthermore, the meter&#8217;s pulse rate (pulses per minute) can be scaled into a <strong>rate-of-flow signal<\/strong> (eg: gallons per minute) to provide a complete metering picture to the SCADA system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Often, there is a desire to co-connect these same meters to an AMI\/AMR system using a 3-wire encoded AMI signal,  However, if the meter is not natively outfitted with this signal, then a SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#PTE\">model PTE Pulse Encodalizer<\/a><\/strong> can be used to convert the pulse signal into a 3-wire encoded signal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><em>&#8220;But what if the meter&#8217;s pulse signal is already being used by the SCADA system?&#8221;<\/em><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If that is the case, then the pulse signal must first be <strong><em>split<\/em><\/strong> for sharing. The SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APK\">model APK Analog\/Pulse Kit<\/a><\/strong> is especially suitable for this task, as shown in the following illustration. Note that the Analog\/Pulse Kit requires DC mains power (9-36Vdc):<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/08\/APK_Pulse_Splitter_02-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"731\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/08\/APK_Pulse_Splitter_02-1024x731.jpg\" alt=\"\" class=\"wp-image-4304\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/08\/APK_Pulse_Splitter_02-1024x731.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/08\/APK_Pulse_Splitter_02-300x214.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/08\/APK_Pulse_Splitter_02-768x548.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/08\/APK_Pulse_Splitter_02-1536x1096.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/08\/APK_Pulse_Splitter_02-2048x1462.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">In the above illustration, a pulse output signal from a magnetic flow meter is split and co-connected to both a SCADA system and an AMI system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For AMI connectivity, the SCADAmetrics <strong>model PTE Pulse Encodalizer<\/strong> is leveraged to provide a 3-wire encoded AMI signal for flow meters that otherwise do not feature this necessary signal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is important to note that a pulse signal (dry-contact, open-collector, open-drain, etc.) cannot simply be wired in parallel to multiple pulse input devices.  Each pulse input device (PTE Pulse Encodalizer, PLC, RTU, etc&#8230;) provides a unique DC pullup voltage which can damage other parallel devices.  Therefore, an isolated split must be performed using an APK Analog\/Pulse Kit or other equivalent device.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The APK Analog\/Pulse Kit is especially suitable for pulse splitting, because of the following key features:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Its 2 Pulse Outputs are Solid-State Relays, which will not wear out mechanically<\/li>\n\n\n\n<li>Its 2 Pulse Outputs and its Pulse Input are all galvanically isolated from each other<\/li>\n\n\n\n<li>It provides a user-scalable 4-20mA Rate-of-Flow Output, which is often of interest to SCADA users<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Questions?\u2026<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Are you interested in learning more about how SCADAmetrics flow instrumentation can be combined with magmeters and other specialty flow meters to co-connect meters to both SCADA and AMI systems? Give us a call!\u2026 We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Many commercial and industrial flow meters feature a 2-wire, pulse-output that represents a volumetric total signal (eg: gallons). For example: 1 pulse = 1 gallon, or 1 pulse = 10 gallons, etc&#8230; The volumetric pulse signal has historically been used by SCADA (Supervisory Control and Data Acquisition) systems to convey totalized flow. Furthermore, the meter&#8217;s <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=4299\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":2298,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[262,3,295,205,4,284,336,263,283,317,314],"tags":[387,386],"class_list":["post-4299","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-4-20ma-flow-signaling","category-applications","category-magnetic-flow-meters","category-meter-duplexers","category-meteringtechnology","category-neptune-protocol","category-open-channel-flow-meters","category-pulse-signaling","category-sensus-protocol","category-ultrasonic-flow-meters","category-venturi-flow-meters","tag-pulse-signal-splitter","tag-pulse-splitter"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/4299","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4299"}],"version-history":[{"count":6,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/4299\/revisions"}],"predecessor-version":[{"id":4307,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/4299\/revisions\/4307"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/2298"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4299"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=4299"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=4299"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}