{"id":4107,"date":"2026-03-09T00:04:41","date_gmt":"2026-03-09T06:04:41","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=4107"},"modified":"2026-03-11T13:43:25","modified_gmt":"2026-03-11T19:43:25","slug":"scadametrics-instrumentation-and-badger-flow-meters","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=4107","title":{"rendered":"SCADAmetrics Instrumentation and Badger Flow Meters"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<p><strong><a href=\"https:\/\/www.badgermeter.com\/\">Badger Meter<\/a><\/strong> (Milwaukee, Wisconsin, USA) manufactures a broad line of flow meters and AMI\/AMR systems, serving the municipal water utility industry. Here at <strong><a href=\"http:\/\/www.scadametrics.com\" target=\"_blank\" rel=\"noreferrer noopener\">SCADAmetrics (Wildwood, MO)<\/a><\/strong>, we manufacture flow metering instrumentation in support of this industry, with the stated mission of helping users extend such meters for enhanced SCADA interoperability and functionality.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"528\" height=\"394\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_E_Series_001.jpg\" alt=\"\" class=\"wp-image-4108\" style=\"width:428px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_E_Series_001.jpg 528w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_E_Series_001-300x224.jpg 300w\" sizes=\"auto, (max-width: 528px) 100vw, 528px\" \/><figcaption class=\"wp-element-caption\"><strong>Badger Flow Meters Include the E-Series Ultrasonic, along with Positive Displacement, Turbine, and Magnetic Flow Meters.<\/strong><\/figcaption><\/figure>\n\n\n\n<p>Like many manufacturers of AWWA-style flow meters, Badger&#8217;s signaling options are focused upon their 3-wire, encoded protocol for interfacing with AMI\/AMR endpoints.  However, Badger also offers pulse and 4-20mA SCADA signaling options, as well.  Badger&#8217;s 3-wire encoded protocol implementation is capable of transmitting <strong>9-digit, fine-resolution totalization<\/strong> information \u2014 which SCADAmetrics instrumentation leverages to generate <strong>additional<\/strong> industrial signal and display options \u2014 thereby providing an extended ability to solve the unique challenges facing the <strong>SCADA, Telemetry, and Building Automation spheres<\/strong>.<\/p>\n\n\n\n<p>For the new Badger E-Series Ultrasonic flow meter, SCADAmetrics recommends that this meter be purchased with dual-outputs:\u00a0 3-Wire Encoded + Scaled Pulse, as this will provide maximum flexibility for SCADA signaling expansion.<\/p>\n\n\n\n<p>The purpose of this document is to provide a summary of several of the main SCADAmetrics devices and methods that we offer to extend the broad line of Badger flow meters.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Badger Compatible Cable Types<\/h2>\n\n\n\n<p>Optimal SCADA performance is delivered when the most suitable meter signal cable type is provided. Cable types include 3-wire encoded, 2-wire pulse, and in instances where available \u2014 <em>both<\/em>.<\/p>\n\n\n\n<p>When encoded cables are utilized, it is always recommended that the Badger meter be pre-programmed to provide the finest resolution available and the maximum number of digits or &#8220;wheels&#8221; (usually 9 or 8):<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"610\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_Encoded_Resolution_001-1024x610.jpg\" alt=\"\" class=\"wp-image-4112\" style=\"width:350px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_Encoded_Resolution_001-1024x610.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_Encoded_Resolution_001-300x179.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_Encoded_Resolution_001-768x458.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_Encoded_Resolution_001.jpg 1032w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>When pulse cables are utilized, it is always recommended that the Badger meter be pre-programmed to provide the finest resolution pulse available:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"617\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_Pulse_Resolution_001-1024x617.jpg\" alt=\"\" class=\"wp-image-4111\" style=\"aspect-ratio:1.659669054087429;width:361px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_Pulse_Resolution_001-1024x617.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_Pulse_Resolution_001-300x181.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_Pulse_Resolution_001-768x463.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_Pulse_Resolution_001.jpg 1032w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">1. Concurrent Basic SCADA and AMI from Encoded-Only Flow Meter<\/h2>\n\n\n\n<p>The following illustrates how a model EMP Signalizer display can be paired with an encoded-only Badger flow meter to provide basic SCADA signaling, while preserving the existing AMI signaling to the water utility. The SCADA signaling is in the form of a 4-20 milliamp output, a pulse-per-volume output, and a meter fault alarm output. Please note that the 4-20 milliamp SCADA output requires a 8\/9-digit encoded signal from the meter. Excellent for custody-transfer stations. Also excellent for utility-owned water meters at commercial and industrial buildings, where the building owner desires a meter reading into its BMS system, without requiring the installation of a new water meter, or without interfering with the utility&#8217;s AMI system. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#EMP\" target=\"_blank\" rel=\"noreferrer noopener\">Model EMP Signalizer<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_AMI_001.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1008\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_AMI_001-1024x1008.jpg\" alt=\"\" class=\"wp-image-4125\" style=\"width:344px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_AMI_001-1024x1008.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_AMI_001-300x295.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_AMI_001-768x756.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_AMI_001-1536x1512.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_AMI_001-2048x2016.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">2. Concurrent Basic SCADA and Remote Display from Encoded-Only Flow Meter<\/h2>\n\n\n\n<p>The following illustrates how an encoded-only Badger flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, meter fault alarm), and a Remote Wall Display. Excellent for custody-transfer stations and commercial buildings. Design Basis: <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APK\" target=\"_blank\" rel=\"noreferrer noopener\">Model EMP Signalizer<\/a><\/strong> and <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#TMD\" target=\"_blank\" rel=\"noreferrer noopener\">Model TMD TheMeterDisplay<\/a><\/strong>.  Coming soon! \u2014 TMD Support for Badger E-Series advanced alarm flags (Temperature &amp; Pressure).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_001.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"940\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_001-940x1024.jpg\" alt=\"\" class=\"wp-image-4118\" style=\"aspect-ratio:0.917970084010655;width:353px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_001-940x1024.jpg 940w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_001-275x300.jpg 275w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_001-768x837.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_001-1410x1536.jpg 1410w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_001-1880x2048.jpg 1880w\" sizes=\"auto, (max-width: 940px) 100vw, 940px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">3. Concurrent Basic SCADA, AMI, and Remote Display from Encoded-Only Flow Meter<\/h2>\n\n\n\n<p>The following illustrates how an encoded-only Badger flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, meter fault alarm), AMI signaling (3-Wire Encoder Protocol), and a Remote Wall Display. Excellent for custody-transfer stations and commercial buildings. Design Basis: <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APK\" target=\"_blank\" rel=\"noreferrer noopener\">Model EMP Signalizer<\/a><\/strong> and <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#TMD\" target=\"_blank\" rel=\"noreferrer noopener\">Model TMD TheMeterDisplay<\/a><\/strong>.  Coming soon! \u2014 TMD Support for Badger E-Series advanced alarm flags (Temperature &amp; Pressure).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_AMI_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"824\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_AMI_001-1024x824.jpg\" alt=\"\" class=\"wp-image-4119\" style=\"width:362px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_AMI_001-1024x824.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_AMI_001-300x241.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_AMI_001-768x618.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_AMI_001-1536x1236.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_TMD_AMI_001-2048x1649.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">4. Advanced SCADA from Encoded Flow Meter<\/h2>\n\n\n\n<p>The gold standard of SCADA connectivity for a flow meter is transmission of the <em>&#8220;true&#8221;<\/em> meter reading into the SCADA system with zero error.  We call that &#8220;revenue-grade accuracy&#8221;.  The following illustrates how a Badger flow meter can be enhanced to provide advanced SCADA signaling (Modbus, Allen-Bradley EtherNet\/IP). Excellent for custody-transfer pumping and valve stations where revenue-grade accuracy is of paramount importance. Also excellent for military bases and educational facilities. Design Basis: <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#EM100\" data-type=\"URL\" data-id=\"https:\/\/www.scadametrics.com\/products\/products.htm#EM100\" target=\"_blank\" rel=\"noreferrer noopener\">Model EM.100 EtherMeter<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"706\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_001-1024x706.jpg\" alt=\"\" class=\"wp-image-4117\" style=\"width:363px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_001-1024x706.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_001-300x207.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_001-768x530.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_001-1536x1059.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_001-2048x1413.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">5. Concurrent Advanced SCADA and AMI from Encoded Flow Meter<\/h2>\n\n\n\n<p>The gold standard of SCADA connectivity for a flow meter is transmission of the <em>&#8220;true&#8221;<\/em> meter reading into the SCADA system with zero error.  We call that &#8220;revenue-grade accuracy&#8221;.  The following illustrates how a Badger flow meter can be enhanced to provide advanced SCADA signaling (Modbus, Allen-Bradley EtherNet\/IP), while at the <em>same time<\/em> provide signaling to a connected AMI System. Excellent for custody-transfer metering, pumping, and valve stations where revenue-grade accuracy is of paramount importance for both the SCADA system and AMI system. Also excellent for commercial and industrial facilities who wish to internally track the utility-owned water meter. The inclusion of a model SDA or SDAW Duplexer (illustrated below) ensures concurrent AMI connectivity. Design Basis: <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#EM100\" data-type=\"URL\" data-id=\"https:\/\/www.scadametrics.com\/products\/products.htm#EM100\" target=\"_blank\" rel=\"noreferrer noopener\">Model EM.100 EtherMeter<\/a><\/strong> and <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#SDA\">Model SDA SCADA Duplexer for AMI<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_SDA_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"805\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_SDA_001-1024x805.jpg\" alt=\"\" class=\"wp-image-4116\" style=\"aspect-ratio:1.272064739009039;width:401px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_SDA_001-1024x805.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_SDA_001-300x236.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_SDA_001-768x603.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_SDA_001-1536x1207.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EM100_SDA_001-2048x1609.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">6. Basic SCADA from Encoded-Only Flow Meter<\/h2>\n\n\n\n<p>The following illustrates how an encoded-only Badger flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, meter fault alarm). Excellent for well and pumping stations, as well as commercial building submetering. Design Basis: <a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#EMP\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Model EMP Signalizer<\/strong>:<\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_001.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"957\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_001-1024x957.jpg\" alt=\"\" class=\"wp-image-4113\" style=\"aspect-ratio:1.0700210978862306;width:365px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_001-1024x957.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_001-300x280.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_001-768x718.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_001-1536x1435.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_EMP_001-2048x1914.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">7. Basic SCADA Outputs from Pulse Flow Meter<\/h2>\n\n\n\n<p>The following illustrates how a Badger pulse-type flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, flow switch, meter fault alarm). Excellent for well and pumping stations and commercial submetering. Design Basis: SCADAmetrics <a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APK\" target=\"_blank\" rel=\"noreferrer noopener\">Model APK Analog-Pulse Kit<\/a>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_001.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"988\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_001-1024x988.jpg\" alt=\"\" class=\"wp-image-4120\" style=\"aspect-ratio:1.036461225245234;width:370px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_001-1024x988.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_001-300x289.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_001-768x741.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_001-1536x1481.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_001-2048x1975.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">8. Visual Batching, Visual Rate-of-Flow, plus SCADA Outputs from Pulse Flow Meter<\/h2>\n\n\n\n<p>The following illustrates how a Badger pulse-type flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, flow switch, meter fault alarm), along with an always-ON operator flow and batch display. Excellent for well and pumping stations. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APKPLUS\" target=\"_blank\" rel=\"noreferrer noopener\">Model APK.PLUS Analog-Pulse Kit, Plus<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"595\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_001-595x1024.jpg\" alt=\"\" class=\"wp-image-4121\" style=\"width:381px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_001-595x1024.jpg 595w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_001-174x300.jpg 174w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_001-768x1322.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_001-892x1536.jpg 892w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_001-1190x2048.jpg 1190w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_001-scaled.jpg 1487w\" sizes=\"auto, (max-width: 595px) 100vw, 595px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">9. Basic SCADA plus AMI from a Dual-Output Flow Meter (Encoded+Pulse)<\/h2>\n\n\n\n<p>The following illustrates how a Badger dual-output flow meter (encoded+pulse) can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, flow switch, meter fault alarm) \u2014 and concurrent AMI capability. Excellent for well and pumping stations and custody-transfer stations. Design Basis: SCADAmetrics <a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APK\" target=\"_blank\" rel=\"noreferrer noopener\">Model APK Analog-Pulse Kit<\/a>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_AMI_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"902\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_AMI_001-1024x902.jpg\" alt=\"\" class=\"wp-image-4123\" style=\"width:365px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_AMI_001-1024x902.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_AMI_001-300x264.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_AMI_001-768x677.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_AMI_001-1536x1353.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_AMI_001-2048x1805.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">10. Visual Batching, Visual Rate-of-Flow, plus SCADA Outputs from Dual-Output (Encoded+Pulse) Meter<\/h2>\n\n\n\n<p>The following illustrates how a Badger dual-output (encoded+pulse) flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, flow switch, meter fault alarm), along with an always-ON operator flow and batch display \u2014 and concurrent AMI capability. Excellent for well and pumping stations and custody-transfer stations. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APKPLUS\" target=\"_blank\" rel=\"noreferrer noopener\">Model APK.PLUS Analog-Pulse Kit, Plus<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_AMI_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"666\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_AMI_001-666x1024.jpg\" alt=\"\" class=\"wp-image-4124\" style=\"aspect-ratio:0.6503959915952804;width:367px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_AMI_001-666x1024.jpg 666w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_AMI_001-195x300.jpg 195w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_AMI_001-768x1180.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_AMI_001-1000x1536.jpg 1000w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_AMI_001-1333x2048.jpg 1333w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_PLUS_AMI_001-scaled.jpg 1666w\" sizes=\"auto, (max-width: 666px) 100vw, 666px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">11. Basic SCADA plus Remote Display plus AMI from a Dual-Output Flow Meter (Encoded+Pulse)<\/h2>\n\n\n\n<p>The following illustrates how a Badger dual-output flow meter (encoded+pulse) can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, flow switch, meter fault alarm) \u2014 and concurrent AMI capability. Excellent for well and pumping stations and custody-transfer stations. Design Basis: SCADAmetrics <a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APK\" target=\"_blank\" rel=\"noreferrer noopener\">Model APK Analog-Pulse Kit<\/a>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_TMD_AMI_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"749\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_TMD_AMI_001-1024x749.jpg\" alt=\"\" class=\"wp-image-4122\" style=\"aspect-ratio:1.367173592391028;width:371px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_TMD_AMI_001-1024x749.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_TMD_AMI_001-300x219.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_TMD_AMI_001-768x562.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_TMD_AMI_001-1536x1123.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_APK_TMD_AMI_001-2048x1498.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">12. Dual-AMI Connectivity<\/h2>\n\n\n\n<p>The following illustrates how a Badger flow meter can provide AMI signaling to two separate systems. Excellent for custody-transfer stations, where both the water buyer and seller desire meter connectivity to their separate respective AMI systems. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#UDA\" target=\"_blank\" rel=\"noreferrer noopener\">Model UDA Universal Duplexer for AMI<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_UDA_001.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"968\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_UDA_001-968x1024.jpg\" alt=\"\" class=\"wp-image-4132\" style=\"aspect-ratio:0.9453138737471426;width:363px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_UDA_001-968x1024.jpg 968w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_UDA_001-284x300.jpg 284w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_UDA_001-768x812.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_UDA_001-1452x1536.jpg 1452w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_UDA_001.jpg 1834w\" sizes=\"auto, (max-width: 968px) 100vw, 968px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">13. Concurrent AMI Connectivity and Remote Visual Display<\/h2>\n\n\n\n<p>The following illustrates how a model TMD display can work with a Badger flow meter to provide AMI signaling to the water utility, while concurrently providing a visual remote display whose reading is a perfect match to the Badger meter register total. Furthermore, if the Badger register is programmed for 8 or 9 digit resolution, then this fine resolution will enable the display of rate-of-flow (GPM, lpm), as well. Excellent for utility-owned water meters at commercial and industrial buildings, where the building owner desires a meter reading without requiring entry to a vault or confined-space. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#TMD\" target=\"_blank\" rel=\"noreferrer noopener\">Model TMD TheMeterDisplay<\/a><\/strong>.  Coming soon! \u2014 TMD Support for Badger E-Series advanced alarm flags (Temperature &amp; Pressure).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_AMI_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"726\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_AMI_001-1024x726.jpg\" alt=\"\" class=\"wp-image-4115\" style=\"aspect-ratio:1.4105033257222277;width:373px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_AMI_001-1024x726.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_AMI_001-300x213.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_AMI_001-768x545.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_AMI_001-1536x1089.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_AMI_001-2048x1452.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">14. Remote Visual Display<\/h2>\n\n\n\n<p>The following illustrates how a model TMD display can work with a Badger flow meter to provide a remote visual display to an otherwise not-easily accessible water meter. The remote display provides a perfect match to the reading displayed on the Badger meter register. Furthermore, if the Badger meter register is programmed for 8 or 9 digit resolution, then this fine resolution will enable the display of rate-of-flow (GPM, lpm), as well. Excellent for customer-owned sub-meters at commercial and industrial buildings, where the building owner desires a meter reading without requiring entry to a vault or confined-space. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#TMD\" target=\"_blank\" rel=\"noreferrer noopener\">Model TMD TheMeterDisplay<\/a><\/strong>. Coming soon! \u2014 TMD Support for Badger E-Series advanced alarm flags (Temperature &amp; Pressure).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_001.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"943\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_001-1024x943.jpg\" alt=\"\" class=\"wp-image-4114\" style=\"aspect-ratio:1.0859070434484013;width:372px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_001-1024x943.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_001-300x276.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_001-768x707.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_001-1536x1415.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Badger_TMD_001.jpg 1986w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">15. Connect Pulse Flow Meters to Badger Orion AMI<\/h2>\n\n\n\n<p>The Pulse Encodalizer is a battery-powered signal converter with integral 9-digit display. It counts pulses from most 2-wire, pulse-type flow meters (magmeters, wastewater meters, gas meters, steam meters, reclaimed water meters, irrigation meters, etc&#8230;) \u2014 and converts to a 3-Wire Encoded protocol \u2014 thereby providing compatibility with Badger&#8217;s Orion AMI system.  Badger&#8217;s lineup of magmeters already feature encoded outputs, so the Encodalizer is not needed for those.  However, there are a large number of 3rd-party pulse type meters that can benefit from the Encodalizer, whose battery pack offers a life up to 10 years and is user-replaceable.<\/p>\n\n\n\n<p>The following illustrates how a model PTE Pulse Encodalizer&#x2122; can transform a pulse-type flow meter into an Orion-compatible encoder-type flow meter. Excellent for wastewater lift stations, irrigation points-of-sale, sewer deduct meters, natural gas meters. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#TMD\" target=\"_blank\" rel=\"noreferrer noopener\">Model PTE Pulse Encodalizer<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Teledyne_ISCO_PTE_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"589\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Teledyne_ISCO_PTE_001-1024x589.jpg\" alt=\"\" class=\"wp-image-4126\" style=\"aspect-ratio:1.7385680098311882;width:362px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Teledyne_ISCO_PTE_001-1024x589.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Teledyne_ISCO_PTE_001-300x173.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Teledyne_ISCO_PTE_001-768x442.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Teledyne_ISCO_PTE_001-1536x884.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2026\/03\/Teledyne_ISCO_PTE_001-2048x1178.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>&#8230;click to zoom.<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>Would you like a downloadable PDF copy of this article? \u2014 Click <strong><a href=\"https:\/\/scadametrics.com\/PDF\/Badger_SCADAmetrics_01.pdf\">HERE<\/a><\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Want to Learn More?&#8230;<\/h2>\n\n\n\n<p>Are you interested in learning more about how SCADAmetrics flow instrumentation, when paired with Badger flow meters, can provide a wealth of value-added SCADA and visual display options? Give us a call!\u2026 We\u2019ll be glad to discuss the details!<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Badger Meter (Milwaukee, Wisconsin, USA) manufactures a broad line of flow meters and AMI\/AMR systems, serving the municipal water utility industry. Here at SCADAmetrics (Wildwood, MO), we manufacture flow metering instrumentation in support of this industry, with the stated mission of helping users extend such meters for enhanced SCADA interoperability and functionality. Like many manufacturers <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=4107\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":4108,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[262,3,8,295,250,205,4,5,263,283,317],"tags":[373,108,374,375],"class_list":["post-4107","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-4-20ma-flow-signaling","category-applications","category-general","category-magnetic-flow-meters","category-meter-display-technology","category-meter-duplexers","category-meteringtechnology","category-modbusprotocol","category-pulse-signaling","category-sensus-protocol","category-ultrasonic-flow-meters","tag-badger","tag-badger-meter","tag-badger-orion","tag-orion"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/4107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4107"}],"version-history":[{"count":41,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/4107\/revisions"}],"predecessor-version":[{"id":4166,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/4107\/revisions\/4166"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/4108"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4107"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=4107"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=4107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}