{"id":409,"date":"2011-11-03T09:31:13","date_gmt":"2011-11-03T15:31:13","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=409"},"modified":"2022-10-15T16:11:11","modified_gmt":"2022-10-15T22:11:11","slug":"4-20ma-analog-flow-proportional-outputs-using-the-ethermeter","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=409","title":{"rendered":"4-20mA Analog Flow-Proportional Outputs Using The EtherMeter"},"content":{"rendered":"<p><div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div><strong>[2022 Edit: The technology in this article has been deprecated, due to our introduction of the Model EMP Signalizer<em>&#x2122;<\/em> and Model APK (and APK.PLUS) Analog Pulse Kit, which supplant the need for the equipment and techniques described in this article.]<\/strong><\/p>\n<p>In most cases, EtherMeter users will collect flow rate data via the device&#8217;s digital Ethernet and Serial communication channels.\u00a0 Digital communication protocols include MODBUS (TCP\/RTU\/ASCII), DF1, and EtherNet\/IP&#x2122;.<\/p>\n<p>However, in some instances, the user may wish to interface to 4-20mA analog signals that are proportional to flow.\u00a0 Replacement of Sensus ACT-PAK instrumentation is just one possible use.\u00a0 However, in this case, the EtherMeter is capable of deriving the 4-20mA signal from either an encoder-type or a pulse-output-type flow meter.\u00a0 Within the Setup Menu, the EtherMeter also permits the user to specify the 4-20mA span (the flow-rate that corresponds to 20mA).<\/p>\n<p>When used with an encoder-type flow meter, it is important to recognize the limitations of this type of 4-20mA signal.\u00a0 Because it is not\u00a0based upon a\u00a0hard real-time flow-rate signal, the user should therefore exercise caution when using the 4-20mA signal to drive a PID control loop.<\/p>\n<div id=\"attachment_413\" style=\"width: 287px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2011\/11\/Sany1351b.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-413\" class=\"size-medium wp-image-413\" title=\"SCADAmetrics Analog Flow-Output Demonstrator Panel\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2011\/11\/Sany1351b-277x300.jpg\" alt=\"\" width=\"277\" height=\"300\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2011\/11\/Sany1351b-277x300.jpg 277w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2011\/11\/Sany1351b-947x1024.jpg 947w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2011\/11\/Sany1351b-184x200.jpg 184w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2011\/11\/Sany1351b.jpg 1921w\" sizes=\"auto, (max-width: 277px) 100vw, 277px\" \/><\/a><p id=\"caption-attachment-413\" class=\"wp-caption-text\">SCADAmetrics Analog Flow-Output Demonstrator Panel<\/p><\/div>\n<p>This document describes the wiring procedures and EtherMeter settings that are required for 4-20mA output signaling.\u00a0 Note that the EtherMeter requires Special Firmware plus an\u00a0ADAM-4024 module (by Advantech)\u00a0for this option, and so the purchaser must ensure that the Analog-Output Firmware+Module option is selected when buying at the <a href=\"http:\/\/shop.scadametrics.com\">eStore<\/a>.\u00a0 Also, it is important to note that when using this option, the ADAM-4024 module consumes the serial port; and therefore any digital communications to the EtherMeter must occur via the Ethernet port.<\/p>\n<p>Detailed procedures are available in a new Application Note posted\u00a0in the <a href=\"https:\/\/scadametrics.com\/docs\/docs.htm\">SCADAmetrics Documentation Center<\/a>:<\/p>\n<p><a href=\"https:\/\/scadametrics.com\/PDF\/App_Note_015.pdf\">LINK TO APP NOTE<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>[2022 Edit: The technology in this article has been deprecated, due to our introduction of the Model EMP Signalizer&#x2122; and Model APK (and APK.PLUS) Analog Pulse Kit, which supplant the need for the equipment and techniques described in this article.] In most cases, EtherMeter users will collect flow rate data via the device&#8217;s digital Ethernet <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=409\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":413,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3],"tags":[11,12,51,13,59,30],"class_list":["post-409","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","tag-4-20-milliamp","tag-analog-signal","tag-flow-meter","tag-flow-rate","tag-rate-of-flow","tag-water-meter"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=409"}],"version-history":[{"count":31,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/409\/revisions"}],"predecessor-version":[{"id":2440,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/409\/revisions\/2440"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/413"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}