{"id":3766,"date":"2025-09-10T22:23:53","date_gmt":"2025-09-11T04:23:53","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=3766"},"modified":"2025-09-10T22:23:53","modified_gmt":"2025-09-11T04:23:53","slug":"connecting-the-ametek-usonic-r-to-an-ami-system-using-the-mbe-encodalizer","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=3766","title":{"rendered":"Connecting the Ametek USonic-R to an AMI System using the MBE Encodalizer"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">James Mimlitz &#8216;Slim&#8217;, SCADAmetrics<\/p><\/div>\n\n\n\n<p><strong><a href=\"https:\/\/www.drexelbrook.com\/\">AMETEK Drexelbrook (Horsham, PA)<\/a><\/strong> is known throughout the world as a leader in level measurement technology, with over five decades of experience providing level solutions to virtually every major industry, including water, wastewater, chemical, petrochemical, refining, power, food, pharmaceutical, pulp &amp; paper, mining, automotive, and many others.<\/p>\n\n\n\n<p>The <strong><a href=\"https:\/\/www.drexelbrook.com\/products\/continuous-level-measurement\/ultrasonic-level-measurement\/usonic-r-ultrasonic-level-transmitter\">USonic-R<\/a><\/strong> (pictured below) is AMETEK&#8217;s mains-powered level measurement system that is often deployed in <strong><a href=\"https:\/\/en.wikipedia.org\/wiki\/Weir\">weir<\/a><\/strong> and <strong><a href=\"https:\/\/en.wikipedia.org\/wiki\/Flume\">flume<\/a><\/strong> open-channel flow applications.  It features a level sensing capability that can be used to calculate <strong><em>rate-of-flow<\/em><\/strong> (example: GPM), plus an accumulator functionality that can be used to calculate <strong><em>volumetric totalization<\/em><\/strong> (example: Gallons).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"950\" height=\"714\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_01.jpg\" alt=\"\" class=\"wp-image-3768\" style=\"width:371px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_01.jpg 950w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_01-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_01-768x577.jpg 768w\" sizes=\"auto, (max-width: 950px) 100vw, 950px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>AMETEK \/ Drexelbrook USonic-R<\/strong><\/figcaption><\/figure>\n\n\n\n<p>The <strong>USonic-R<\/strong> features traditional 4-20 milliamp and pulse SCADA signals, as well as fieldbus protocols.  Like most mains-powered process transmitters, the USonic-R does not offer native AMI\/AMR-compatibility. However, SCADAmetrics is pleased to announce that today\u2019s firmware release for the <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#MBE\">Model MBE Modbus Encodalizer\u2122<\/a><\/strong> now adds Sensus and Neptune encoder protocols to this important flow meter, so that it may now be easily integrated into today\u2019s modern AMI\/AMR systems!<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>The following illustrates a typical application of the <strong>USonic-R\/Encodalizer Pair<\/strong> into a potable water distribution or wastewater system \u2014 where\u00a0<strong>both<\/strong>\u00a0AMI and SCADA signaling made are possible:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1011\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_03-1011x1024.jpg\" alt=\"\" class=\"wp-image-3780\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_03-1011x1024.jpg 1011w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_03-296x300.jpg 296w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_03-768x778.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_03-1517x1536.jpg 1517w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_03-2022x2048.jpg 2022w\" sizes=\"auto, (max-width: 1011px) 100vw, 1011px\" \/><figcaption class=\"wp-element-caption\"><strong>SCADAmetrics MBE Modbus Encodalizer and AMETEK USonic-R \u2013 Illustrated Principle of Operation<\/strong><\/figcaption><\/figure>\n\n\n\n<p>Connection of the Encodalizer to the USonic-R could not be easier: Two (2) wires interconnect the instruments: Modbus<sup>+<\/sup>(B) and Modbus<sup>\u2013<\/sup>(A). Configuration of the Encodalizer is also straightforward, requiring setup via 16 integral DIP switches from a lookup table.<\/p>\n\n\n\n<p>The USonic-R factory default Modbus communication settings should not be modified, with the exception that that RS.485 should be activated (RS.232 is default).<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">USonic-R \/ AMI &#8211; Basic Wiring<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_04-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"706\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_04-706x1024.jpg\" alt=\"\" class=\"wp-image-3782\" style=\"width:463px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_04-706x1024.jpg 706w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_04-207x300.jpg 207w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_04-768x1114.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_04-1059x1536.jpg 1059w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_04-1412x2048.jpg 1412w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_04-scaled.jpg 1765w\" sizes=\"auto, (max-width: 706px) 100vw, 706px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">USonic-R \/ AMI \/ SCADA &#8211; Advanced Wiring<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_05-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"740\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_05-1024x740.jpg\" alt=\"\" class=\"wp-image-3784\" style=\"width:684px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_05-1024x740.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_05-300x217.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_05-768x555.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_05-1536x1110.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/09\/Ametek_05-2048x1480.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Documentation<\/h2>\n\n\n\n<p>Would you like to download a PDF copy of our <strong>USonic-R \/ Encodalizer Application Note<\/strong>? \u2014 Click\u00a0<strong><a href=\"https:\/\/www.scadametrics.com\/PDF\/MBE_AMETEK_USonic_R_001.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Here<\/a><\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Want to Learn More?&#8230;<\/h2>\n\n\n\n<p>Are you interested in learning more about how SCADAmetrics flow instrumentation, when paired with the AMETEK \/ Drexelbrook USonic-R flow meter, can provide concurrent AMI and SCADA signaling options? Give us a call!\u2026 We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>AMETEK Drexelbrook (Horsham, PA) is known throughout the world as a leader in level measurement technology, with over five decades of experience providing level solutions to virtually every major industry, including water, wastewater, chemical, petrochemical, refining, power, food, pharmaceutical, pulp &amp; paper, mining, automotive, and many others. The USonic-R (pictured below) is AMETEK&#8217;s mains-powered level <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=3766\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":3768,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,4,5,284,336,283,317,314],"tags":[],"class_list":["post-3766","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-meteringtechnology","category-modbusprotocol","category-neptune-protocol","category-open-channel-flow-meters","category-sensus-protocol","category-ultrasonic-flow-meters","category-venturi-flow-meters"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3766","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3766"}],"version-history":[{"count":17,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3766\/revisions"}],"predecessor-version":[{"id":3788,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3766\/revisions\/3788"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/3768"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3766"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3766"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}