{"id":3695,"date":"2025-07-03T15:21:46","date_gmt":"2025-07-03T21:21:46","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=3695"},"modified":"2025-10-29T18:35:07","modified_gmt":"2025-10-30T00:35:07","slug":"connect-a-rosemount-8750w-magnetic-flow-meter-to-an-ami-network","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=3695","title":{"rendered":"Connect a Rosemount Magnetic Flow Meter to an AMI Network"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<p><strong><a href=\"https:\/\/www.emerson.com\/en-us\/automation\/measurement-instrumentation\/flow-measurement\/about-magnetic\">Emerson \/ Rosemount<\/a><\/strong> manufactures a broad line of flow meters, serving the industrial process, municipal water, and municipal wastewater industries. Here at&nbsp;<strong><a href=\"http:\/\/www.scadametrics.com\/\" target=\"_blank\" rel=\"noreferrer noopener\">SCADAmetrics (Wildwood, MO)<\/a><\/strong>, we manufacture flow metering instrumentation in support of these industries, with the stated mission of helping users extend such meters for enhanced SCADA and AMI interoperability and functionality.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"795\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote-1024x795.jpg\" alt=\"\" class=\"wp-image-3699\" style=\"width:521px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote-1024x795.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote-300x233.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote-768x596.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote.jpg 1152w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Rosemount 8750w Magnetic Flow Meter with Remote Transmitter<\/figcaption><\/figure>\n\n\n\n<p>Like many manufacturers of process-oriented flow meters, Rosemount&#8217;s signaling options are focused upon 4-20 milliamp, pulse, Modbus, and HART. Today, the new&nbsp;<strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#PTE\">SCADAmetrics model PTE Pulse Encodalizer\u2122<\/a><\/strong>&nbsp;is able to leverage the available pulse output on the <strong>Model 8750w magnetic flow meter<\/strong> (and others) to generate additional AMI signaling and display options \u2014 thereby bridging the gap to solve the unique challenges facing the&nbsp;<strong>Utility AMI sphere<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"697\" height=\"450\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001.jpg\" alt=\"\" class=\"wp-image-3131\" style=\"width:423px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001.jpg 697w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001-300x194.jpg 300w\" sizes=\"auto, (max-width: 697px) 100vw, 697px\" \/><\/a><figcaption class=\"wp-element-caption\">Model PTE Pulse Encodalizer<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"569\" height=\"599\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01.jpg\" alt=\"\" class=\"wp-image-3154\" style=\"width:393px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01.jpg 569w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01-285x300.jpg 285w\" sizes=\"auto, (max-width: 569px) 100vw, 569px\" \/><\/a><figcaption class=\"wp-element-caption\">PTE Pulse Encodalizer \u2013 Illustrated Principle of Operation<\/figcaption><\/figure>\n\n\n\n<p>Within each Rosemount 8750w (and certain other model) Transmitter, a pulse-per-volume output terminal is available. This output can be converted into a 3-wire encoded signal \u2014 using a SCADAmetrics model PTE Pulse Encodalizer \u2014 to provide a utility AMI system with forward totalized flow.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Forward Totalization Reported to AMI System<\/h2>\n\n\n\n<p>The following graphics illustrate how the Pulse Encodalizer can be used to transmit Forward Totalization to an AMI\/AMR system. Most (but not all) municipal metering applications are uni-directional (forward flow only). Note the connection from the 8750w Transmitter Pulse Output Terminals (Pulse+,Pulse-) to the Pulse Input Terminals of the Encodalizer (Terminals 2,3):<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote_PTE-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1008\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote_PTE-1008x1024.jpg\" alt=\"\" class=\"wp-image-3702\" style=\"width:593px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote_PTE-1008x1024.jpg 1008w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote_PTE-295x300.jpg 295w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote_PTE-768x780.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote_PTE-1512x1536.jpg 1512w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_remote_PTE-2016x2048.jpg 2016w\" sizes=\"auto, (max-width: 1008px) 100vw, 1008px\" \/><\/a><figcaption class=\"wp-element-caption\">Rosemount 8750w with Remote Transmitter Connected to an AMI System.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_field_mount_PTE-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_field_mount_PTE-927x1024.jpg\" alt=\"\" class=\"wp-image-3701\" style=\"width:575px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_field_mount_PTE-927x1024.jpg 927w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_field_mount_PTE-272x300.jpg 272w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_field_mount_PTE-768x848.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_field_mount_PTE-1391x1536.jpg 1391w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_field_mount_PTE-1855x2048.jpg 1855w\" sizes=\"auto, (max-width: 927px) 100vw, 927px\" \/><\/a><figcaption class=\"wp-element-caption\">Rosemount 8750w with Field-Mount Transmitter Connected to an AMI System.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_Fort_Worth.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_Fort_Worth-768x1024.jpg\" alt=\"\" class=\"wp-image-3704\" style=\"width:678px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_Fort_Worth-768x1024.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_Fort_Worth-225x300.jpg 225w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_Fort_Worth-1152x1536.jpg 1152w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/Rosemount_8750_Fort_Worth.jpg 1512w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><figcaption class=\"wp-element-caption\">Rosemount 8750w Magnetic Flow Meter Connected to an AMI System via SCADAmetrics PTE Encodalizer.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p>The&nbsp;<strong>PTE Pulse Encodalizer<\/strong>&nbsp;translates the Rosemount 8750w magnetic flow meter pulse count to a connected AMI\/AMR system using the industry-standard, 3-wire encoded protocols: both&nbsp;<strong>Sensus Protocol<\/strong>&nbsp;and&nbsp;<strong>Neptune Protocol<\/strong>. Therefore, all major AMI systems are supported.<\/p>\n\n\n\n<p>The Encodalizer is powered by a user-replaceable battery pack, which offers a life up to 10 years. The Encodalizer features a 9-digit LCD display of the Pulse Count \/ Totalization. When commissioning the Encodalizer, the user should pre-edit the 9 digits \u2014 in order to&nbsp;<strong>synchronize<\/strong>&nbsp;(match) with the totalization displayed on the LCD screen of the Rosemount 8750w.<\/p>\n\n\n\n<p>Anticipated Encodalizer \/ Rosemount 8750w applications include (but are not limited to):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Connect distribution magmeters to potable water AMI systems<\/li>\n\n\n\n<li>Connect wastewater custody transfer flow meters to AMI systems<\/li>\n\n\n\n<li>Connect wastewater lift station flow meters to AMI systems<\/li>\n<\/ul>\n\n\n\n<p>In addition to the Rosemount 8750w, the PTE Pulse Encodalizer can be used to connect other types of Rosemount pulse meters to AMI systems, as well. The only requirement is that the connected flow meter provide a 2-wire, passive pulse-per-volume output.<\/p>\n\n\n\n<p>Although this article focuses on Rosemount flow meters, the Pulse Encodalizer is able to count pulses from most 2-wire, pulse-type flow meters (magmeters, wastewater meters, gas meters, steam meters, reclaimed water meters, irrigation meters, etc\u2026) \u2014 and convert to the industry-standard 3-Wire Encoded protocol.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Want to Learn More?\u2026<\/h2>\n\n\n\n<p>Are you interested in learning more about how SCADAmetrics flow instrumentation, when paired with Rosemount magnetic flow meters, can provide a wealth of value-added AMI and visual display options? Give us a call!\u2026 We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Emerson \/ Rosemount manufactures a broad line of flow meters, serving the industrial process, municipal water, and municipal wastewater industries. Here at&nbsp;SCADAmetrics (Wildwood, MO), we manufacture flow metering instrumentation in support of these industries, with the stated mission of helping users extend such meters for enhanced SCADA and AMI interoperability and functionality. Like many manufacturers <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=3695\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":3699,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,295,4,284,263,283,317,314],"tags":[347,341],"class_list":["post-3695","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-magnetic-flow-meters","category-meteringtechnology","category-neptune-protocol","category-pulse-signaling","category-sensus-protocol","category-ultrasonic-flow-meters","category-venturi-flow-meters","tag-emerson","tag-rosemount"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3695","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3695"}],"version-history":[{"count":12,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3695\/revisions"}],"predecessor-version":[{"id":3935,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3695\/revisions\/3935"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/3699"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3695"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3695"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3695"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}