{"id":3548,"date":"2025-03-03T10:26:47","date_gmt":"2025-03-03T16:26:47","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=3548"},"modified":"2025-04-12T15:15:15","modified_gmt":"2025-04-12T21:15:15","slug":"connecting-a-rosemount-3490-transmitter-to-an-ami-system","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=3548","title":{"rendered":"Connecting a Rosemount 3490 Transmitter to an AMI System"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<p><strong><a href=\"http:\/\/www.rosemount.com\">Rosemount<\/a><\/strong> manufactures a broad line of process instrumentation and flow meters, serving the industrial process, municipal water, and municipal wastewater industries. Here at <strong><a href=\"http:\/\/www.scadametrics.com\" target=\"_blank\" rel=\"noreferrer noopener\">SCADAmetrics (Wildwood, MO)<\/a><\/strong>, we manufacture flow metering instrumentation in support of these industries, with the stated mission of helping users extend such meters for enhanced SCADA and AMI interoperability and functionality.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_02.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"676\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_02-1024x676.jpg\" alt=\"\" class=\"wp-image-3550\" style=\"width:431px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_02-1024x676.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_02-300x198.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_02-768x507.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_02.jpg 1146w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">Rosemount 3490 Flow Transmitter<\/figcaption><\/figure>\n\n\n\n<p>Like many manufacturers of process-oriented flow instrumentation, Rosemount&#8217;s signaling options are focused upon 4-20 milliamp, pulse, Modbus, and HART.<\/p>\n\n\n\n<p>Today, the new <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#PTE\">SCADAmetrics model PTE Pulse Encodalizer\u2122<\/a><\/strong> is able to leverage the available Relay (Pulse) output from a <strong><a href=\"https:\/\/www.emerson.com\/en-us\/catalog\/rosemount-3490-controller\">Rosemount model 3490 Open-Channel Flow Meter Transmitter<\/a><\/strong> to generate additional AMI signaling and display options \u2014 thereby bridging the gap to solve the unique challenges facing the <strong>Utility AMI sphere<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"697\" height=\"450\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001.jpg\" alt=\"\" class=\"wp-image-3131\" style=\"width:399px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001.jpg 697w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001-300x194.jpg 300w\" sizes=\"auto, (max-width: 697px) 100vw, 697px\" \/><\/a><figcaption class=\"wp-element-caption\">Model PTE Pulse Encodalizer<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"569\" height=\"599\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01.jpg\" alt=\"\" class=\"wp-image-3154\" style=\"width:324px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01.jpg 569w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01-285x300.jpg 285w\" sizes=\"auto, (max-width: 569px) 100vw, 569px\" \/><\/a><figcaption class=\"wp-element-caption\">PTE Pulse Encodalizer &#8211; Illustrated Principle of Operation<\/figcaption><\/figure>\n\n\n\n<p>Within each Rosemount 3490 Transmitter, programmable relay outputs are available.  One of these outputs can be configured to provide a pulse-per-volume output to a SCADAmetrics model PTE Encodalizer and thereby connect to a utility AMI system.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Totalization Reported to AMI System<\/h2>\n\n\n\n<p>The following graphic illustrates how the Pulse Encodalizer can be used to transmit Totalization to an AMI\/AMR system.  Note the connection from the Rosemount 3490 Relay (Pulse) Output.  In this example, 3490 Relay #1 (Terminals 11, 13) is connected to the Pulse Input (Terminals 2, 3) of the Encodalizer:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_pte_01-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"776\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_pte_01-1024x776.jpg\" alt=\"\" class=\"wp-image-3555\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_pte_01-1024x776.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_pte_01-300x227.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_pte_01-768x582.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_pte_01-1536x1164.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/03\/rosemount_3490_pte_01-2048x1552.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">Totalization From a Rosemount 3490 Reported to an AMI\/AMR System.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p>The <strong>PTE Pulse Encodalizer<\/strong> translates the Rosemount 3490 totalizer pulse count to a connected AMI\/AMR system using the industry-standard, 3-wire encoded protocols: both <strong>Sensus Protocol<\/strong> and <strong>Neptune Protocol<\/strong>. Therefore, all major AMI systems are supported.<\/p>\n\n\n\n<p>The Encodalizer is powered by a user-replaceable battery pack, which offers a life up to 10 years. The Encodalizer features a 9-digit LCD display of the Pulse Count \/ Totalization. When commissioning the Encodalizer, the user should pre-edit the 9 digits \u2014 in order to <strong>synchronize<\/strong> (match) with the totalization displayed on the LCD screen of the Rosemount 3490.<\/p>\n\n\n\n<p>Anticipated Encodalizer \/ Rosemount 3490 applications include (but are not limited to):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Connect wastewater custody transfer flow meters to AMI systems<\/li>\n\n\n\n<li>Connect wastewater lift station flow meters to AMI systems<\/li>\n<\/ul>\n\n\n\n<p>In addition to the Rosemount 3490, the PTE Pulse Encodalizer can be used to connect other types of Rosemount pulse meters to AMI systems, as well. Examples include the <strong>8750-series Magnetic Flow Meter<\/strong>, and others. The only requirement is that the connected flow meter provide a 2-wire, passive pulse-per-volume output.<\/p>\n\n\n\n<p>Although this article focuses on a Rosemount flow meter, the Pulse Encodalizer is able to count pulses from most 2-wire, pulse-type flow meters (magmeters, wastewater meters, gas meters, steam meters, reclaimed water meters, irrigation meters, etc&#8230;) \u2014 and convert to the industry-standard 3-Wire Encoded protocol.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Want to Learn More?&#8230;<\/h2>\n\n\n\n<p>Are you interested in learning more about how SCADAmetrics flow instrumentation, when paired with a Rosemount open-channel 3490 flow meter, can provide a wealth of value-added AMI and visual display options? Give us a call!\u2026 We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Rosemount manufactures a broad line of process instrumentation and flow meters, serving the industrial process, municipal water, and municipal wastewater industries. Here at SCADAmetrics (Wildwood, MO), we manufacture flow metering instrumentation in support of these industries, with the stated mission of helping users extend such meters for enhanced SCADA and AMI interoperability and functionality. Like <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=3548\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":3554,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[262,3,8,4,284,336,263,283,317,314],"tags":[342,343,159,160,341],"class_list":["post-3548","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-4-20ma-flow-signaling","category-applications","category-general","category-meteringtechnology","category-neptune-protocol","category-open-channel-flow-meters","category-pulse-signaling","category-sensus-protocol","category-ultrasonic-flow-meters","category-venturi-flow-meters","tag-ami-system","tag-amr-system","tag-magmeter","tag-magnetic-flow-meter","tag-rosemount"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3548","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3548"}],"version-history":[{"count":7,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3548\/revisions"}],"predecessor-version":[{"id":3559,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3548\/revisions\/3559"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/3554"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3548"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3548"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3548"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}