{"id":3389,"date":"2025-01-08T10:00:16","date_gmt":"2025-01-08T16:00:16","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=3389"},"modified":"2025-01-08T10:03:08","modified_gmt":"2025-01-08T16:03:08","slug":"connecting-the-siemens-hydroranger-200-to-an-ami-system-using-the-mbe-encodalizer","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=3389","title":{"rendered":"Connecting the Siemens HydroRanger 200 to an AMI System using the MBE Encodalizer"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<p><strong><a href=\"http:\/\/www.siemens.com\">Siemens Industry (Harleysville, PA)<\/a><\/strong> manufactures a broad line of instrumentation for the industrial process sphere, including solutions for flow, level, and pressure. Typical served industries include chemical, food &amp; beverage, power &amp; energy, mining, oil &amp; gas, and water &amp; wastewater.<\/p>\n\n\n\n<p>The <strong><a href=\"https:\/\/www.siemens.com\/us\/en\/products\/automation\/process-instrumentation\/level-measurement\/continuous\/controllers\/multiranger-200-hmi.html\">Siemens HydroRanger 200<\/a><\/strong> (pictured below) is a popular flow meter transmitter that is suitable for a broad range of open-channel water and wastewater flow metering applications. The HydroRanger features traditional 4-20 milliamp and pulse SCADA signals, as well as fieldbus protocols.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"646\" height=\"868\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_01.jpg\" alt=\"\" class=\"wp-image-3392\" style=\"width:286px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_01.jpg 646w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_01-223x300.jpg 223w\" sizes=\"auto, (max-width: 646px) 100vw, 646px\" \/><\/a><figcaption class=\"wp-element-caption\">Siemens HydroRanger 200 Transmitter<\/figcaption><\/figure>\n\n\n\n<p>Like most mains-powered process transmitters, the HydroRanger 200 does not offer native AMI\/AMR-compatibility. However, SCADAmetrics is pleased to announce that today\u2019s firmware release for the <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#MBE\">Model MBE Modbus Encodalizer\u2122<\/a><\/strong> now adds Neptune and Sensus encoder protocols to this important flow meter, so that it may now be easily integrated into today\u2019s modern AMI\/AMR systems!<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>The following illustrates a typical application of the <strong>HydroRanger\/Encodalizer Pair<\/strong> into a potable water distribution or wastewater system \u2014 where\u00a0<strong>both<\/strong>\u00a0AMI and SCADA signaling are desired:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_02-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"786\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_02-1024x786.jpg\" alt=\"\" class=\"wp-image-3394\" style=\"width:783px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_02-1024x786.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_02-300x230.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_02-768x590.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_02-1536x1179.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_02-2048x1573.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">SCADAmetrics MBE Modbus Encodalizer and Siemens HydroRanger &#8211; Illustrated Principle of Operation<\/figcaption><\/figure>\n\n\n\n<p>Connection of the Encodalizer to the HydroRanger could not be easier: Two (2) wires interconnect the instruments: Modbus<sup>+<\/sup>(B) and Modbus<sup>\u2013<\/sup>(A). Configuration of the Encodalizer is also straightforward, requiring setup via 16 integral DIP switches from a lookup table.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">HydroRanger \/ AMI &#8211; Basic Wiring<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_basic_wiring_01-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"871\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_basic_wiring_01-1024x871.jpg\" alt=\"\" class=\"wp-image-3401\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_basic_wiring_01-1024x871.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_basic_wiring_01-300x255.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_basic_wiring_01-768x653.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_basic_wiring_01-1536x1306.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_basic_wiring_01-2048x1741.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">HydroRanger \/ AMI \/ SCADA &#8211; Advanced Wiring<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_advanced_wiring_01-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"675\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_advanced_wiring_01-1024x675.jpg\" alt=\"\" class=\"wp-image-3404\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_advanced_wiring_01-1024x675.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_advanced_wiring_01-300x198.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_advanced_wiring_01-768x506.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_advanced_wiring_01-1536x1013.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/01\/Siemens_HydroRanger_200_advanced_wiring_01-2048x1351.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Documentation<\/h2>\n\n\n\n<p>Would you like to download a PDF copy of our HydroRanger \/ Encodalizer Application Note? \u2014 Click\u00a0<strong><a href=\"https:\/\/www.scadametrics.com\/PDF\/MBE_Siemens_HydroRanger200_001.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Here<\/a><\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Want to Learn More?&#8230;<\/h2>\n\n\n\n<p>Are you interested in learning more about how SCADAmetrics flow instrumentation, when paired with the Siemens HydroRanger flow meter, can provide concurrent AMI and SCADA signaling options? Give us a call!\u2026 We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Siemens Industry (Harleysville, PA) manufactures a broad line of instrumentation for the industrial process sphere, including solutions for flow, level, and pressure. Typical served industries include chemical, food &amp; beverage, power &amp; energy, mining, oil &amp; gas, and water &amp; wastewater. The Siemens HydroRanger 200 (pictured below) is a popular flow meter transmitter that is <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=3389\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":3410,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,8,5,284,336,283],"tags":[],"class_list":["post-3389","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-general","category-modbusprotocol","category-neptune-protocol","category-open-channel-flow-meters","category-sensus-protocol"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3389","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3389"}],"version-history":[{"count":13,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3389\/revisions"}],"predecessor-version":[{"id":3407,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3389\/revisions\/3407"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/3410"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3389"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3389"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3389"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}