{"id":3082,"date":"2024-06-10T10:28:06","date_gmt":"2024-06-10T16:28:06","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=3082"},"modified":"2024-10-03T13:42:36","modified_gmt":"2024-10-03T19:42:36","slug":"migration-to-the-scadametrics-apk-analog-pulse-kit-from-the-sensus-act-pak","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=3082","title":{"rendered":"Migration to the SCADAmetrics &#8216;Analog \/ Pulse Kit&#8217; from the Sensus ACT-PAK"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<p><a href=\"http:\/\/www.sensus.com\"><strong>Sensus, a Xylem Brand (Morrisville, NC)<\/strong><\/a> manufactures a broad line of flow meters and AMI\/AMR systems, serving the municipal water utility industry. Here at <a href=\"https:\/\/scadametrics.com\/\"><strong>SCADAmetrics (Wildwood, MO)<\/strong><\/a>, we manufacture flow metering instrumentation in support of this industry, with the stated mission of helping users extend such meters for enhanced SCADA interoperability and functionality.<\/p>\n\n\n\n<p>With the recently announced discontinuance of the <strong>Sensus ACT-PAK family of instrumentation<\/strong>, there has never been a better time for resellers and users of Sensus C&amp;I flow meters to switch to the <a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APKPLUS\"><strong>SCADAmetrics Analog\/Pulse Kits (model APK and model APK.PLUS)<\/strong>!<\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"687\" height=\"694\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/sensus_act_pak_01.jpg\" alt=\"\" class=\"wp-image-3118\" style=\"width:203px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/sensus_act_pak_01.jpg 687w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/sensus_act_pak_01-297x300.jpg 297w\" sizes=\"auto, (max-width: 687px) 100vw, 687px\" \/><figcaption class=\"wp-element-caption\">Sensus ACT-PAK<\/figcaption><\/figure>\n\n\n\n<p>Our Analog\/Pulse Kit offers features that enable easy SCADA signal conversion from Sensus&#8217; entire lineup of C&amp;I flow meters. Additionally, our newly-designed instruments offer technical superiority in the important areas of <strong>lightning protection<\/strong> and <strong>field-configurability<\/strong>. (Make sure to check out our specifications regarding galvanic isolation.)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-style-default\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Square_001.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" data-id=\"2288\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Square_001.jpg\" alt=\"\" class=\"wp-image-2288\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Square_001.jpg 500w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Square_001-300x300.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Square_001-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><figcaption class=\"wp-element-caption\">Model APK.PLUS<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-style-default\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"850\" height=\"850\" data-id=\"2298\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01.jpg\" alt=\"\" class=\"wp-image-2298\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01.jpg 850w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01-300x300.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01-150x150.jpg 150w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01-768x768.jpg 768w\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" \/><\/a><figcaption class=\"wp-element-caption\">Model APK<\/figcaption><\/figure>\n<figcaption class=\"blocks-gallery-caption wp-element-caption\"><strong>Analog SCADA Interfaces by SCADAmetrics \u2014  for Sensus\u00ae Flow Meters<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Similarities&#8230; Differences&#8230;<\/h2>\n\n\n\n<p><strong><span style=\"text-decoration: underline;\">Mounting:<\/span> <\/strong>Sensus offered a varied assortment of ACT-PAK&#8217;s: 100 Series, 104 Series, 325 Series, 703 Series, 713AC, 1100 Series, 1200DN and 7113 Series.  Certain models were intended to be mounted on a wall, and others were designed to be set upon a tabletop.<\/p>\n\n\n\n<p>At SCADAmetrics, we designed a wall-mount version housed in a NEMA-4X enclosure (model APK.PLUS). And we opted to <strong><em>not<\/em><\/strong> offer a tabletop version, but instead we designed a <strong>DIN-rail-mount version<\/strong> (model APK) for easy integration inside control panels.<\/p>\n\n\n\n<p><strong><span style=\"text-decoration: underline;\">Electrical Surge Protection:<\/span><\/strong> Unlike the ACT-PAK, the SCADAmetrics both models, the APK and APK.PLUS, offer 5 points of galvanic isolation \u2014 and thereby the strongest method of lightning\/surge protection:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Input DC Power Supply<\/li>\n\n\n\n<li>Flow Meter Pulse Interface Circuit<\/li>\n\n\n\n<li>4-20mA Rate-of-Flow Output Signal<\/li>\n\n\n\n<li>Pulse #1 Output Signal<\/li>\n\n\n\n<li>Flow Switch \/ Pulse #2 Output Signal<\/li>\n<\/ul>\n\n\n\n<p><strong><span style=\"text-decoration: underline;\">4-20mA Output Scaling:<\/span><\/strong> Each ACT-PAK was custom-scaled at the <strong><em>factory<\/em><\/strong>, per user specifications, to a desired 20mA rate-of-flow. In this regard, Sensus offered infinite possibilities. The SCADAmetrics models APK and APK.PLUS both offer the user the ability to digitally set the 4-20mA output scale from among 16 logarithmically-spaced choices.  We recognize that this represents a trade-off between fast turnaround and flexibility, and we emphasized fast turnaround. The following scalings are offered:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>GPM (USA): 20, 30, 50, 80, 125, 200, 300, 500, 750, 1200, 2000, 3000, 4600, 7300, 11400, 18000<\/li>\n\n\n\n<li>LPM (CA): 75, 120, 200, 300, 475, 750, 1200, 2000, 3000, 4500, 7000, 11000, 17500, 27500, 43000, 68000<\/li>\n<\/ul>\n\n\n\n<p><strong><span style=\"text-decoration: underline;\">Input Pulse Weight:<\/span><\/strong> Each ACT-PAK was custom-scaled at the factory to match the expected engineering units (Gallons, Cubic Feet, Cubic Meters, Acre-Feet) and pulse weight for a specific flow meter. The SCADAmetrics models APK and APK.PLUS both offer the user the ability to digitally set the registration units and the pulse weight, and therefore any given Analog\/Pulse Kit may be used with any Sensus meter model, size, and units.<\/p>\n\n\n\n<p><strong><span style=\"text-decoration: underline;\">Electrical Safety:<\/span><\/strong> The Analog\/Pulse Kits are powered by an external, NRTL-Listed 120Vac-24Vdc adapter. In contrast, the Sensus ACT-PAK&#8217;s plugged directly into the station 120Vac power source, and those units were not NRTL-Listed.<\/p>\n\n\n\n<p><strong><span style=\"text-decoration: underline;\">Fast Turnaround:<\/span><\/strong> Because the Analog\/Pulse Kits offer the reseller and user the ability to configure the device to match any given meter, fast turnaround is the result.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Sensus Meter Compatibility<\/h2>\n\n\n\n<p>The Analog\/Pulse Kit is compatible with the following Sensus Flow Meters:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Omni-Series T2, C2, F2<\/li>\n\n\n\n<li>Cordonel-Series with Pulse Output Option<\/li>\n\n\n\n<li>HydroVerse<\/li>\n\n\n\n<li>AccuMag<\/li>\n\n\n\n<li>Legacy W-Series Turbo with High-Speed-Pickup Register<\/li>\n\n\n\n<li>Legacy Propeller-Series with HET (Hall Effect Transmitter)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">APK.PLUS &#8211; Analog\/Pulse Kit with Visual Display and Totalizer<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"691\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01-1024x691.jpg\" alt=\"\" class=\"wp-image-2282\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01-1024x691.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01-300x202.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01-768x518.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01.jpg 1427w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">Model APK.PLUS &#8211; Feature Illustration<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">APK &#8211; Analog\/Pulse Kit, DINstrumentation<strong>\u2122<\/strong> Series<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"533\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01-1024x533.jpg\" alt=\"\" class=\"wp-image-2281\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01-1024x533.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01-300x156.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01-768x400.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01.jpg 1494w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">Model APK &#8211; Feature Illustration<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">APK.PLUS Sample Application<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"891\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APKPLUS-891x1024.jpg\" alt=\"\" class=\"wp-image-2938\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APKPLUS-891x1024.jpg 891w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APKPLUS-261x300.jpg 261w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APKPLUS-768x883.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APKPLUS-1336x1536.jpg 1336w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APKPLUS-1781x2048.jpg 1781w\" sizes=\"auto, (max-width: 891px) 100vw, 891px\" \/><figcaption class=\"wp-element-caption\">Example APK.PLUS Application: SCADA Analog Interface for Sensus Omni-Series Water Meter.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"769\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APKPLUS-Magna-1024x769.jpg\" alt=\"\" class=\"wp-image-3328\" style=\"width:537px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APKPLUS-Magna-1024x769.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APKPLUS-Magna-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APKPLUS-Magna-768x577.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APKPLUS-Magna.jpg 1127w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">APK.PLUS Installed at a Pump Station.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">APK Sample Application<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"530\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APK-2-1024x530.jpg\" alt=\"\" class=\"wp-image-2959\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APK-2-1024x530.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APK-2-300x155.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APK-2-768x397.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APK-2-1536x795.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Omni_APK-2-2048x1060.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Example APK Application: SCADA Interface for Sensus Omni-Series Water Meter<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APK_DIN_Panel_01-1024x768.jpg\" alt=\"\" class=\"wp-image-3324\" style=\"width:461px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APK_DIN_Panel_01-1024x768.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APK_DIN_Panel_01-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APK_DIN_Panel_01-768x576.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APK_DIN_Panel_01-1536x1152.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/06\/APK_DIN_Panel_01-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">APK&#8217;s (2) Installed in a Control Panel.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-features\">Key Features \u2013<\/h2>\n\n\n\n<p>\u2022 4-20mA Flow-Proportional Output (3KV Isolation).<br>\u2022 Dry-Contact, Volume-Proportional Output (3.75KV Isolation).<br>\u2022 Dry-Contact Flow-Switch Output (3.75KV Isolation).<\/p>\n\n\n\n<p>\u2022 Compatible with Most Late-Model, Pulse-Type Flow Meters.<br>\u2022 Works with All Popular Registration Units (Gallons, Cubic Feet, Cubic Meters, Acre Feet).<\/p>\n\n\n\n<p>\u2022 No Computer Required! \u2013 Setup via DIP Switches Only!<br>\u2022 Removable Terminal Blocks, Simplified Wiring Procedures.<br>\u2022 NEMA-4X Wall Mount, or Standard 35mm industrial DIN-rail-mount.<br>\u2022 24VDC-Powered (1.5KV Isolation). Low 1.2W Power Consumption.<br>\u2022 Enclosure and Circuit Board: UL 94-VO recognized materials.<br>\u2022 Power Source is NRTL-Listed.<br>\u2022 Simulation-Mode Feature: Emits 12mA and 1 Hz Pulse.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<p><strong><a href=\"https:\/\/www.scadametrics.com\/PDF\/APK_PLUS_01.pdf\">Download PDF Datasheet \/ User Manual Here: Model APK.PLUS &#8216;Analog Pulse Kit&#8217;<\/a><\/strong><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.scadametrics.com\/PDF\/APK_DIN_01.pdf\">Download PDF Datasheet \/ User Manual Here: Model APK &#8216;Analog Pulse Kit&#8217;<\/a><\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<p><\/p>\n\n\n\n<p>To download a PDF Version of this article, click <strong><a href=\"https:\/\/scadametrics.com\/PDF\/Migration_to_APK_from_ACTPAK_01.pdf\">HERE<\/a><\/strong>.<\/p>\n\n\n\n<p>Are you interested in learning how <strong>The Model APK or APK.PLUS Analog Pulse Kit<\/strong> can help to more closely monitor the flow through your Sensus water meters? Give us a call! We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sensus, a Xylem Brand (Morrisville, NC) manufactures a broad line of flow meters and AMI\/AMR systems, serving the municipal water utility industry. Here at SCADAmetrics (Wildwood, MO), we manufacture flow metering instrumentation in support of this industry, with the stated mission of helping users extend such meters for enhanced SCADA interoperability and functionality. With the <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=3082\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":2288,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[262,3,8,250,4,263,317],"tags":[329],"class_list":["post-3082","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-4-20ma-flow-signaling","category-applications","category-general","category-meter-display-technology","category-meteringtechnology","category-pulse-signaling","category-ultrasonic-flow-meters","tag-sensus-act-pak-replacement"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3082","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3082"}],"version-history":[{"count":45,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3082\/revisions"}],"predecessor-version":[{"id":3332,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3082\/revisions\/3332"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/2288"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3082"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3082"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3082"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}