{"id":3068,"date":"2024-07-29T06:56:32","date_gmt":"2024-07-29T12:56:32","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=3068"},"modified":"2025-01-21T02:17:17","modified_gmt":"2025-01-21T08:17:17","slug":"the-pulse-encodalizer-unveiled","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=3068","title":{"rendered":"Pulse Encodalizer\u2122 Unveiled!"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<p>The majority of SCADAmetrics&#8217; instrumentation is focused on connecting flow meters to SCADA, telemetry, and building automation systems. Today, we introduce a new device that helps to connect specialty flow meters to your AMI system: the <strong>model PTE Pulse Encodalizer\u2122<\/strong>!!<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"697\" height=\"450\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001.jpg\" alt=\"\" class=\"wp-image-3131\" style=\"width:407px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001.jpg 697w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/pte_webstore_001-300x194.jpg 300w\" sizes=\"auto, (max-width: 697px) 100vw, 697px\" \/><figcaption class=\"wp-element-caption\">Model PTE Pulse Encodalizer<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Extending AMI Systems to Specialty Flow Meters (Wastewater, etc\u2026)<\/h2>\n\n\n\n<p>Modern <strong><a href=\"https:\/\/en.wikipedia.org\/wiki\/Smart_meter#Advanced_metering_infrastructure\">AMI systems<\/a><\/strong> excel at collecting consumption data from <strong>potable water meters outfitted with 3-wire encoded outputs<\/strong>; and the sophistication of these systems has evolved to such a degree that they have even begun to resemble <strong><a href=\"https:\/\/en.wikipedia.org\/wiki\/SCADA\">SCADA systems<\/a><\/strong> \u2014 providing insight into the operational aspects of the water utility&#8217;s distribution system.<\/p>\n\n\n\n<p>Yet after utility owners have invested to put such infrastructure in place, we are now hearing many operators ask, &#8220;How can we extend the usefulness of our AMI network into specialty meter monitoring? Think: magnetic flow meters, clamp-on ultrasonic meters, wastewater meters, venturi meters, gas meters, electric meters\u2026<\/p>\n\n\n\n<p>For example, a major impediment to adding wastewater meters to an AMI system is the fact that practically no wastewater meters are outfitted with encoded-output signaling (Sensus &amp; Neptune protocols). And while most wastewater meters are equipped with pulse (per volume) output signaling, most AMI systems do not accept this signal.<\/p>\n\n\n\n<p>Example wastewater meters include <strong>magnetic flow meters<\/strong> from <strong>Siemens<\/strong>, <strong>Endress-Hauser<\/strong>, <strong>Seametrics<\/strong>, <strong>Krohne<\/strong>, <strong>Rosemount<\/strong>, &amp; <strong>Foxboro<\/strong>, and others&#8230; plus <strong>open channel meters<\/strong> from <strong>Vega<\/strong>, <strong>Eastech<\/strong>, <strong>Siemens<\/strong>, <strong>Global Water Instrumentation<\/strong>, <strong>ISCO<\/strong>, <strong>Pulsar<\/strong>, and others.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"179\" height=\"263\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Vega_01.jpg\" alt=\"\" class=\"wp-image-3151\"\/><figcaption class=\"wp-element-caption\">Vega Open-Channel Wastewater Meter<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Making Pulse-Output Flow Meters AMI-Compatible<\/h2>\n\n\n\n<p>The new SCADAmetrics Pulse Encodalizer <strong><em>bridges the signal divide<\/em><\/strong> between AMI systems and pulse-type flow meters! The Encodalizer accepts a 2-wire, dry-contact pulse-per-volume signal from a wastewater meter (or any meter), displays the totalization on its 9-digit LCD display, and transmits the totalization to an AMI radio using the 3-wire, industry-standard Neptune or Sensus protocol.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"569\" height=\"599\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01.jpg\" alt=\"\" class=\"wp-image-3154\" style=\"width:356px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01.jpg 569w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/flow_meter_to_ami_01-285x300.jpg 285w\" sizes=\"auto, (max-width: 569px) 100vw, 569px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Encodalizer Feature Highlights:<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2-Wire Pulse Input (Dry Contact Only)<\/li>\n\n\n\n<li>3-Wire Encoded Output (Neptune or Sensus Protocol)<\/li>\n\n\n\n<li>9-Digit LCD Totalizer Display<\/li>\n\n\n\n<li>Ability to Pre-Load Starting Totalizer Reading<\/li>\n\n\n\n<li>Battery-Powered (Future: Mains-Powered, or Hybrid)<\/li>\n\n\n\n<li>Rated for both Outdoor and Indoor Environments<\/li>\n\n\n\n<li>User-Replaceable Batteries (4x CR-123A)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Pulse Encodalizer Internal View<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/PTE_Internals_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"514\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/PTE_Internals_01-1024x514.jpg\" alt=\"\" class=\"wp-image-3163\" style=\"width:638px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/PTE_Internals_01-1024x514.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/PTE_Internals_01-300x150.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/PTE_Internals_01-768x385.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/PTE_Internals_01.jpg 1322w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Photos from our Beta-Testers&#8230;<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Utility: Elkhart, Indiana<\/li>\n\n\n\n<li>Water and Wastewater<\/li>\n\n\n\n<li>AMI System: Neptune 360<\/li>\n\n\n\n<li>Flow Meter: Vega Open-Channel with Pulse Output<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Elkhart_IN_N360_Encodalizer.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"771\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Elkhart_IN_N360_Encodalizer-771x1024.jpg\" alt=\"\" class=\"wp-image-3159\" style=\"width:559px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Elkhart_IN_N360_Encodalizer-771x1024.jpg 771w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Elkhart_IN_N360_Encodalizer-226x300.jpg 226w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Elkhart_IN_N360_Encodalizer-768x1020.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Elkhart_IN_N360_Encodalizer-1157x1536.jpg 1157w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Elkhart_IN_N360_Encodalizer.jpg 1204w\" sizes=\"auto, (max-width: 771px) 100vw, 771px\" \/><\/a><figcaption class=\"wp-element-caption\">Elkhart, Indiana. <\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Utility: City of Fort Worth, Texas<\/li>\n\n\n\n<li>Water and Wastewater<\/li>\n\n\n\n<li>AMI System: Sensus FlexNet<\/li>\n\n\n\n<li>Flow Meter: Rosemount Magnetic Flow Meter with Pulse Output<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_1048.jpeg\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_1048-768x1024.jpeg\" alt=\"\" class=\"wp-image-3160\" style=\"width:558px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_1048-768x1024.jpeg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_1048-225x300.jpeg 225w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_1048-1152x1536.jpeg 1152w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_1048.jpeg 1536w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><figcaption class=\"wp-element-caption\">Fort Worth, Texas<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Facility: Raytheon (Tucson, Arizona)<\/li>\n\n\n\n<li>Natural Gas<\/li>\n\n\n\n<li>AMI System: SCADAmetrics EtherMeter<\/li>\n\n\n\n<li>Flow Meter: Dresser-Roots Rotary Gas Meter with Pulse Output<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-1.jpeg\"><img loading=\"lazy\" decoding=\"async\" width=\"555\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-1-555x1024.jpeg\" alt=\"\" class=\"wp-image-3162\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-1-555x1024.jpeg 555w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-1-163x300.jpeg 163w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-1-768x1416.jpeg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-1-833x1536.jpeg 833w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-1.jpeg 1024w\" sizes=\"auto, (max-width: 555px) 100vw, 555px\" \/><\/a><figcaption class=\"wp-element-caption\">Raytheon (Tucson, Arizona)<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Facility: LB Water (PA)<\/li>\n\n\n\n<li>Potable Water<\/li>\n\n\n\n<li>AMI System: Sensus FlexNet<\/li>\n\n\n\n<li>Flow Meter: Bermad PRV\/Meter Combo<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-scaled.jpeg\"><img loading=\"lazy\" decoding=\"async\" width=\"598\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-598x1024.jpeg\" alt=\"\" class=\"wp-image-3171\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-598x1024.jpeg 598w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-175x300.jpeg 175w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-768x1315.jpeg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-897x1536.jpeg 897w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-1196x2048.jpeg 1196w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Image-scaled.jpeg 1496w\" sizes=\"auto, (max-width: 598px) 100vw, 598px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Utility: Milbank WinWater SD<\/li>\n\n\n\n<li>Potable Water<\/li>\n\n\n\n<li>AMI System: Mueller MiNET<\/li>\n\n\n\n<li>Flow Meter: Rosemount MagMeter<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Attachment.jpeg\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Attachment-768x1024.jpeg\" alt=\"\" class=\"wp-image-3174\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Attachment-768x1024.jpeg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Attachment-225x300.jpeg 225w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Attachment-1152x1536.jpeg 1152w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/Attachment.jpeg 1440w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Electric Power Meter<\/li>\n\n\n\n<li>AMI System: Badger Orion<\/li>\n\n\n\n<li>Meter: Leviton Model 2000<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_9951-scaled.jpeg\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_9951-768x1024.jpeg\" alt=\"\" class=\"wp-image-3226\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_9951-768x1024.jpeg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_9951-225x300.jpeg 225w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_9951-1152x1536.jpeg 1152w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_9951-1536x2048.jpeg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_9951-scaled.jpeg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_0125.jpeg\"><img loading=\"lazy\" decoding=\"async\" width=\"770\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_0125-770x1024.jpeg\" alt=\"\" class=\"wp-image-3230\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_0125-770x1024.jpeg 770w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_0125-225x300.jpeg 225w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_0125-768x1022.jpeg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2024\/07\/IMG_0125.jpeg 962w\" sizes=\"auto, (max-width: 770px) 100vw, 770px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>&#8230; and more photos will be posted in the future&#8230;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Want to Learn More?&#8230;<\/h2>\n\n\n\n<p>Are you interested in learning more about how SCADAmetrics flow instrumentation can be leveraged to expand the capabilities of your AMI system to include wastewater &amp; other types of meters? Give us a call!\u2026 We\u2019ll be glad to discuss the details!<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n","protected":false},"excerpt":{"rendered":"<p>The majority of SCADAmetrics&#8217; instrumentation is focused on connecting flow meters to SCADA, telemetry, and building automation systems. Today, we introduce a new device that helps to connect specialty flow meters to your AMI system: the model PTE Pulse Encodalizer\u2122!! Extending AMI Systems to Specialty Flow Meters (Wastewater, etc\u2026) Modern AMI systems excel at collecting <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=3068\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":3131,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[262,3,295,250,4,284,263,283,317,314],"tags":[331,161,330],"class_list":["post-3068","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-4-20ma-flow-signaling","category-applications","category-magnetic-flow-meters","category-meter-display-technology","category-meteringtechnology","category-neptune-protocol","category-pulse-signaling","category-sensus-protocol","category-ultrasonic-flow-meters","category-venturi-flow-meters","tag-pulse-to-encoder","tag-ui-1203","tag-ui1203"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3068","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3068"}],"version-history":[{"count":36,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3068\/revisions"}],"predecessor-version":[{"id":3530,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/3068\/revisions\/3530"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/3131"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3068"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3068"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3068"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}