{"id":2823,"date":"2023-12-05T22:16:38","date_gmt":"2023-12-06T04:16:38","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=2823"},"modified":"2023-12-06T17:30:49","modified_gmt":"2023-12-06T23:30:49","slug":"connecting-a-venturi-flow-meter-to-an-ami-or-scada-system","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=2823","title":{"rendered":"Connecting a Venturi Flow Meter (or any 4-20mA Flow Meter) to an AMI or SCADA System"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile is-resized\" style=\"grid-template-columns:34% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"871\" height=\"674\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venturi_Meter_01.jpg\" alt=\"\" class=\"wp-image-2825 size-full\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venturi_Meter_01.jpg 871w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venturi_Meter_01-300x232.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venturi_Meter_01-768x594.jpg 768w\" sizes=\"auto, (max-width: 871px) 100vw, 871px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong>Venturi-Type Flow Meters<\/strong> are utilized within the municipal water industry to measure flows both within the water treatment plant, as well as within distribution. The Venturi flow measurement is based upon measuring the pressure drop between two sections of the tube with differing diameters. Often times, Venturi meters are outfitted with only a 4-20 milliamp flow rate signal output, yet the owner may benefit from monitoring totalization as well.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 31%\"><div class=\"wp-block-media-text__content\">\n<p>In order to totalize the flow, a discrete integral must be calculated of the 4-20mA flow signal, with respect to time. Programmable Logic Controllers (PLC&#8217;s) are capable of performing such an integral, and are often utilized to this effect. However, SCADAmetrics is pleased to introduce a simplified, hardware-only solution, based on our new device: the <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#MTP\">model MTP &#8220;Milliamp-to-Pulse Converter&#8221;<\/a><\/strong>.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"394\" height=\"516\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/MTP_Web_01.jpg\" alt=\"\" class=\"wp-image-2828 size-full\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/MTP_Web_01.jpg 394w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/MTP_Web_01-229x300.jpg 229w\" sizes=\"auto, (max-width: 394px) 100vw, 394px\" \/><\/figure><\/div>\n\n\n\n<p>The model MTP monitors the 4-20 milliamp rate-of-flow signal from a 4-20mA flow meter, and emits a pulse output, where each pulse represents a fixed volume of water. This pulse may then be accumulated within an <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#EM100\">EtherMeter<\/a><\/strong>, which in turn can report the totalization to a connected <strong>SCADA system<\/strong>, a connected <strong>AMI system<\/strong>, or both.<\/p>\n\n\n\n<p>It is important to stress that the <strong>MTP\/EtherMeter<\/strong> combination is suitable for <strong><span style=\"text-decoration: underline;\">any<\/span><\/strong> flow meter which is equipped with a 4-20mA output only. Other types may include certain <strong>Vortex meters<\/strong>, <strong>magnetic flow meters<\/strong>, etc&#8230;<\/p>\n\n\n\n<p>After integration of such a system, if used for custody-transfer and\/or billing applications, it is incumbent upon the user to determine the accuracy of the overall system and perform calibration adjustments, as necessary.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Illustration: Venturi-to-SCADA Connection:<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_01-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"708\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_01-1024x708.jpg\" alt=\"\" class=\"wp-image-2830\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_01-1024x708.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_01-300x207.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_01-768x531.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_01-1536x1061.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_01-2048x1415.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Illustration: Venturi-to-SCADA <span style=\"text-decoration: underline;\">and<\/span> AMI Connection:<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_AMI_01-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"579\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_AMI_01-1024x579.jpg\" alt=\"\" class=\"wp-image-2831\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_AMI_01-1024x579.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_AMI_01-300x170.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_AMI_01-768x434.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_AMI_01-1536x868.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Venture_SCADA_AMI_01-2048x1157.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>SCADA Connection<\/strong><\/h2>\n\n\n\n<p>The EtherMeter provides a robust SCADA connection, as it can transmit both <strong>totalization<\/strong> and <strong>rate-of-flow<\/strong> using modern industrial Ethernet protocols, such as <strong>Modbus\/TCP<\/strong> and <strong>Allen-Bradley EtherNet\/IP<\/strong>. It may also transmit the metering data using modern industrial Serial protocols, such as <strong>Modbus\/RTU<\/strong> and <strong>Allen-Bradley DF1<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>AMI Connection<\/strong><\/h2>\n\n\n\n<p>When a SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#MBE\">model MBE Encodalizer<\/a><\/strong> is added to the system, the totalization may be transmitted to an AMI endpoint, such as those offered by Neptune, Master Meter, Metron-Farnier, Honeywell, Mueller Systems, Zenner, Sensus, Badger, Itron, Kamstrup, and others&#8230;<\/p>\n\n\n\n<p>The MBE Encodalizer outputs an industry-standard, 3-wire encoded signal formatted as either <strong>Neptune-protocol<\/strong> or <strong>Sensus-protocol<\/strong> (user-selectable via dip switches).<\/p>\n\n\n\n<p>Additional in-depth procedures may be studied within <strong><a href=\"https:\/\/www.scadametrics.com\/PDF\/App_Note_034.pdf\">SCADAmetrics Application Note #34 (PDF)<\/a><\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Want to Learn More?&#8230;<\/h2>\n\n\n\n<p>Are you interested in learning more about how SCADAmetrics flow instrumentation, when paired with a 4-20 milliamp-only flow meter, can provide a wealth of value-added SCADA and AMI options? Give us a call!\u2026 We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Venturi-Type Flow Meters are utilized within the municipal water industry to measure flows both within the water treatment plant, as well as within distribution. The Venturi flow measurement is based upon measuring the pressure drop between two sections of the tube with differing diameters. Often times, Venturi meters are outfitted with only a 4-20 milliamp <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=2823\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":2826,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[262,3,4,5,284,263,6,283,314],"tags":[316,315],"class_list":["post-2823","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-4-20ma-flow-signaling","category-applications","category-meteringtechnology","category-modbusprotocol","category-neptune-protocol","category-pulse-signaling","category-rockwell-protocols","category-sensus-protocol","category-venturi-flow-meters","tag-totalizaing-milliamp","tag-totalizing-4-20-milliamp"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2823"}],"version-history":[{"count":15,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2823\/revisions"}],"predecessor-version":[{"id":2845,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2823\/revisions\/2845"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/2826"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}