{"id":2625,"date":"2023-12-02T13:17:43","date_gmt":"2023-12-02T19:17:43","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=2625"},"modified":"2025-04-30T22:50:08","modified_gmt":"2025-05-01T04:50:08","slug":"scada-signaling-from-master-meters-octave-and-others","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=2625","title":{"rendered":"SCADAmetrics Instrumentation and Master Meter Flow Meters"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<p><strong><a href=\"http:\/\/www.mastermeter.com\" target=\"_blank\" rel=\"noreferrer noopener\">Master Meter Inc (Mansfield, TX)<\/a><\/strong> manufactures a broad line of flow meters and AMI\/AMR systems, serving the municipal water utility industry. Here at <strong><a rel=\"noreferrer noopener\" href=\"http:\/\/www.scadametrics.com\" target=\"_blank\">SCADAmetrics (Wildwood, MO)<\/a><\/strong>, we manufacture flow metering instrumentation in support of this industry, with the stated mission of helping users extend such meters for enhanced SCADA interoperability and functionality.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/06\/MasterMeter_Octave_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"934\" height=\"704\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/06\/MasterMeter_Octave_01.jpg\" alt=\"\" class=\"wp-image-2666\" style=\"width:360px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/06\/MasterMeter_Octave_01.jpg 934w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/06\/MasterMeter_Octave_01-300x226.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/06\/MasterMeter_Octave_01-768x579.jpg 768w\" sizes=\"auto, (max-width: 934px) 100vw, 934px\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>Master Meter Flow Meters Include the Octave Ultrasonic (pictured above), the Sonata, plus their Mechanical Flow Meters with AccuLinx and eLinx Registers.<\/strong><\/figcaption><\/figure>\n\n\n\n<p>Like many manufacturers of AWWA-style flow meters, Master Meter&#8217;s signaling options are focused upon their 3-wire, encoded protocol for interfacing with AMI\/AMR endpoints. Master Meter&#8217;s encoded protocol is capable of transmitting <strong>8-digit, fine-resolution totalization<\/strong> information \u2014 which SCADAmetrics instrumentation leverages to generate <strong>additional<\/strong> industrial signal and display options \u2014 thereby bridging the gap to solve the unique challenges facing the <strong>SCADA, Telemetry, and Building Automation spheres<\/strong>.<\/p>\n\n\n\n<p>The purpose of this document is to provide a summary of several of the main SCADAmetrics devices and methods that we offer to extend the broad line of Master Meter flow meters.<\/p>\n\n\n\n<p><strong><span style=\"text-decoration: underline;\">Note 1:<\/span><\/strong> The examples illustrated within this article feature Master Meter&#8217;s ultrasonic <strong>Octave<\/strong> flow meter. However, all solutions are equally compatible with Master Meter&#8217;s Sonata meter, along with its electromechanical flow meters when outfitted with Master Meter&#8217;s <strong><a href=\"https:\/\/www.mastermeter.com\/products\/acculinx-encoder-register\/\">AccuLinx<\/a><\/strong> or <strong><a href=\"https:\/\/www.mastermeter.com\/products\/elinx-interpreter\/\">eLinx<\/a><\/strong> encoder registers.<\/p>\n\n\n\n<p><strong><span style=\"text-decoration: underline;\">Note 2:<\/span><\/strong> It is important to note that standard, cabled versions of the Master Meter registers are utilized in all of the illustrated examples below, as the integrated radio registers do not provide the encoded signal cable required by SCADAmetrics instrumentation. However, all illustrated solutions are compatible with Master Meter&#8217;s <strong><a href=\"https:\/\/www.mastermeter.com\/wp-content\/uploads\/3G-AMR-XTR-Endpoint-External-Transciever.pdf\">XTR MIU<\/a><\/strong>. <\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">1. Concurrent Basic SCADA and AMI<\/h2>\n\n\n\n<p>The following illustrates how an Octave flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, flow switch), plus AMI signaling (3-wire encoder protocol). The Octave meter should be outfitted with dual-output communications option (Encoded + Open Drain Pulse). Excellent for custody-transfer pump and metering stations. Also excellent for utility-owned water meters at commercial and industrial buildings, where the building owner desires a meter reading into its BMS system, without requiring the installation of a new water meter, or without interfering with the utility\u2019s AMI system. Design Basis:&nbsp;<strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APK\" target=\"_blank\" rel=\"noreferrer noopener\">Model APK Analog-Pulse Kit<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"715\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI-1024x715.jpg\" alt=\"\" class=\"wp-image-2779\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI-1024x715.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI-300x209.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI-768x536.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI-1536x1072.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI-2048x1429.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">2. Concurrent Basic SCADA, AMI, and Remote Display<\/h2>\n\n\n\n<p>The following illustrates how an Octave flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, flow switch), AMI signaling (3-wire encoder protocol), and a Remote Wall Display. Excellent for custody-transfer stations and commercial buildings. Design Basis:&nbsp;<strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APK\" target=\"_blank\" rel=\"noreferrer noopener\">Model APK Analog-Pulse Kit<\/a><\/strong>&nbsp;and&nbsp;<strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#TMD\" target=\"_blank\" rel=\"noreferrer noopener\">Model TMD TheMeterDisplay<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI_TMD-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"795\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI_TMD-1024x795.jpg\" alt=\"\" class=\"wp-image-2784\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI_TMD-1024x795.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI_TMD-300x233.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI_TMD-768x597.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI_TMD-1536x1193.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK_AMI_TMD-2048x1591.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">3. Advanced SCADA<\/h2>\n\n\n\n<p>The following illustrates how a Master Meter Octave flow meter can provide advanced SCADA signaling (Modbus, Allen-Bradley EtherNet\/IP). Excellent for custody-transfer pumping and valve stations where revenue-grade accuracy is of paramount importance. Also excellent for military bases and educational facilities. Design Basis: <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#EM100\" data-type=\"URL\" data-id=\"https:\/\/www.scadametrics.com\/products\/products.htm#EM100\" target=\"_blank\" rel=\"noreferrer noopener\">Model EM.100 EtherMeter<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"693\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter-1024x693.jpg\" alt=\"\" class=\"wp-image-2788\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter-1024x693.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter-300x203.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter-768x519.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter-1536x1039.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter-2048x1385.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">4. Concurrent Advanced SCADA and AMI<\/h2>\n\n\n\n<p>The following illustrates how an Octave flow meter can provide advanced SCADA signaling (Modbus, Allen-Bradley EtherNet\/IP), while at the same time provide signaling to a connected AMI System. Excellent for custody-transfer metering, pumping, and valve stations where revenue-grade accuracy is of paramount importance for both the SCADA system and AMI system. Also excellent for commercial and industrial facilities who wish to internally track the utility-owned water meter. The inclusion of a model SDA or SDAW Duplexer (illustrated below) ensures concurrent AMI connectivity. Design Basis:&nbsp;<strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#EM100\" target=\"_blank\" rel=\"noreferrer noopener\">Model EM.100 EtherMeter<\/a><\/strong>&nbsp;and&nbsp;<strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#SDA\">Model SDA SCADA Duplexer for AMI<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter_SDA-1-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"647\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter_SDA-1-1024x647.jpg\" alt=\"\" class=\"wp-image-2929\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter_SDA-1-1024x647.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter_SDA-1-300x189.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter_SDA-1-768x485.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter_SDA-1-1536x970.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EtherMeter_SDA-1-2048x1293.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">5. Basic SCADA<\/h2>\n\n\n\n<p>The following illustrates how a Master Meter Octave flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, flow switch). Excellent for well and pumping stations, as well as commercial buildings. Design Basis: <a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#EMP\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Model APK Analog\/Pulse Ki<\/strong>t:<\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"583\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK-1024x583.jpg\" alt=\"\" class=\"wp-image-2790\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK-1024x583.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK-300x171.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK-768x438.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK-1536x875.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APK-2048x1167.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">6. Visual Batching, Visual Rate-of-Flow, plus Basic SCADA Outputs<\/h2>\n\n\n\n<p>The following illustrates how a Master Meter Octave flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, flow switch, meter fault alarm), along with an always-ON operator flow and batch display. Excellent for well and pumping stations. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APKPLUS\" target=\"_blank\" rel=\"noreferrer noopener\">Model APK.PLUS Analog-Pulse Kit, Plus<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS-1-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"868\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS-1-868x1024.jpg\" alt=\"\" class=\"wp-image-2927\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS-1-868x1024.jpg 868w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS-1-254x300.jpg 254w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS-1-768x906.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS-1-1302x1536.jpg 1302w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS-1-1737x2048.jpg 1737w\" sizes=\"auto, (max-width: 868px) 100vw, 868px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">7. Visual Batching, Visual Rate-of-Flow, plus Basic SCADA Outputs, plus Concurrent AMI<\/h2>\n\n\n\n<p>The following illustrates how a Master Meter Octave flow meter can provide basic SCADA signaling (4-20 milliamp, pulse-per-volume, flow switch, meter fault alarm), along with an always-ON operator flow and batch display and concurrent AMI connectivity. Excellent for well and pumping stations. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#APKPLUS\" target=\"_blank\" rel=\"noreferrer noopener\">Model APK.PLUS Analog-Pulse Kit, Plus<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS_AMI-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"760\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS_AMI-760x1024.jpg\" alt=\"\" class=\"wp-image-2968\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS_AMI-760x1024.jpg 760w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS_AMI-223x300.jpg 223w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS_AMI-768x1035.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS_AMI-1140x1536.jpg 1140w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS_AMI-1520x2048.jpg 1520w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_APKPLUS_AMI-scaled.jpg 1900w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">8. Dual-AMI Connectivity<\/h2>\n\n\n\n<p>The following illustrates how a Master Meter Octave\/Sonata\/ACCULINX\/ELINX flow meter can provide AMI signaling to two separate systems. Excellent for custody-transfer stations, where both the water buyer and seller desire meter connectivity to their separate respective AMI systems. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#UDA\" target=\"_blank\" rel=\"noreferrer noopener\">Model UDA Universal Duplexer for AMI<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_UDA.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"982\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_UDA-1024x982.jpg\" alt=\"\" class=\"wp-image-2796\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_UDA-1024x982.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_UDA-300x288.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_UDA-768x737.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_UDA-1536x1473.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_UDA.jpg 1836w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">9. Concurrent AMI Connectivity and Remote Visual Display<\/h2>\n\n\n\n<p>The following illustrates how a model TMD display can work with a Master Meter Octave\/Sonata\/ACCULINX\/ELINX flow meter to provide AMI signaling to the water utility, while concurrently providing a visual remote display whose reading is a perfect match to the Master Meter register total. Furthermore, the TMD can also provide a rate-of-flow (gpm, lpm) display, as well. Excellent for utility-owned water meters at commercial and industrial buildings, where the building owner desires a meter reading without requiring entry to a vault or confined-space. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#TMD\" target=\"_blank\" rel=\"noreferrer noopener\">Model TMD TheMeterDisplay<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_TMD.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"790\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_TMD-1024x790.jpg\" alt=\"\" class=\"wp-image-2799\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_TMD-1024x790.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_TMD-300x232.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_TMD-768x593.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_TMD-1536x1186.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_TMD-2048x1581.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">10. Retrofit Basic SCADA Connectivity to AMI-Connected Meter<\/h2>\n\n\n\n<p>The following illustrates how a model EMP Signalizer can be applied to a Master Meter Octave\/Sonata\/ACCULINX\/ELINX flow meter that is outfitted with an encoded output module to provide basic SCADA signaling, while preserving the existing AMI signaling to the water utility.  The SCADA signaling is in the form of a pulse-per-volume output. Furthermore, if the Octave\/Sonata\/ELINX\/ACCULINX register is programmed to transmit 8-digits resolution, then a 4-20 milliamp SCADA signal is also provided (requires Octave\/Sonata setting ENCODER_UPDATE_PERIOD = 60s). Excellent for utility-owned water meters at commercial and industrial buildings, where the building owner desires a meter reading into its BMS system, without requiring the installation of a new water meter, or without interfering with the utility&#8217;s AMI system. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#EMP\" target=\"_blank\" rel=\"noreferrer noopener\">Model EMP Signalizer<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"579\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP-1024x579.jpg\" alt=\"\" class=\"wp-image-3219\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP-1024x579.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP-300x170.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP-768x435.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP-1536x869.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP-2048x1159.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">11. Basic SCADA and Remote Display Added to AMI-Connected Meter<\/h2>\n\n\n\n<p>The following illustrates how a model EMP Signalizer and TMD TheMeterDisplay can be applied to a Master Meter Octave\/Sonata\/ELINX\/ACCULINX flow meter that is outfitted with an encoded output module to provide basic SCADA signaling and a Remote Display, while preserving the existing AMI signaling to the water utility. The SCADA signaling is in the form of a pulse-per-volume output. Furthermore, if the Octave\/Sonata\/ACCULINX\/ELINX register is programmed to transmit 8-digits resolution, then a 4-20 milliamp SCADA signal is also provided (requires Octave\/Sonata setting ENCODER_UPDATE_PERIOD = 60s). Excellent for utility-owned water meters at commercial and industrial buildings, where the building owner desires a meter reading into its BMS system and a remote visual display, without requiring the installation of a new water meter, or without interfering with the utility&#8217;s AMI system. Design Basis: SCADAmetrics <strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#EMP\" target=\"_blank\" rel=\"noreferrer noopener\">Model EMP Signalizer<\/a><\/strong> and <a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#TMD\"><strong>Model TMD TheMeterDisplay<\/strong><\/a>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP_TMD-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"803\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP_TMD-1024x803.jpg\" alt=\"\" class=\"wp-image-3216\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP_TMD-1024x803.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP_TMD-300x235.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP_TMD-768x602.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP_TMD-1536x1205.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_EMP_TMD-2048x1606.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">12. Connect Pulse Flow Meters to AMI<\/h2>\n\n\n\n<p>The following illustrates how a model PTE Pulse Encodalizer\u2122 can transform a pulse-type flow meter into an encoder-type flow meter. The Pulse Encodalizer is a battery-powered signal converter with integral 9-digit display. It counts pulses from most 2-wire, pulse-type flow meters (magmeters, wastewater meters, gas meters, steam meters, reclaimed water meters, irrigation meters, etc\u2026) \u2014 and converts to a 3-Wire Encoded protocol. The battery pack offers a life up to 10 years and is user-replaceable. Excellent for wastewater lift stations, irrigation points-of-sale, sewer deduct meters, natural gas meters. Design Basis: SCADAmetrics&nbsp;<strong><a href=\"https:\/\/www.scadametrics.com\/products\/products.htm#TMD\" target=\"_blank\" rel=\"noreferrer noopener\">Model PTE Pulse Encodalizer<\/a><\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_PTE.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_PTE-768x1024.jpg\" alt=\"\" class=\"wp-image-3653\" style=\"width:466px;height:auto\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_PTE-768x1024.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_PTE-225x300.jpg 225w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_PTE-1152x1536.jpg 1152w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_PTE-1536x2048.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2023\/12\/Octave_PTE.jpg 1899w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>Would you like a downloadable PDF copy of this article? \u2014 Click <strong><a href=\"https:\/\/www.scadametrics.com\/PDF\/Octave_SCADAmetrics_01.pdf\">HERE<\/a><\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Want to Learn More?&#8230;<\/h2>\n\n\n\n<p>Are you interested in learning more about how SCADAmetrics flow instrumentation, when paired with Master Meter flow meters, can provide a wealth of value-added SCADA and visual display options? Give us a call!\u2026 We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Master Meter Inc (Mansfield, TX) manufactures a broad line of flow meters and AMI\/AMR systems, serving the municipal water utility industry. Here at SCADAmetrics (Wildwood, MO), we manufacture flow metering instrumentation in support of this industry, with the stated mission of helping users extend such meters for enhanced SCADA interoperability and functionality. Like many manufacturers <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=2625\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":2666,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[262,3,8,250,205,4,5,263,6,283],"tags":[302],"class_list":["post-2625","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-4-20ma-flow-signaling","category-applications","category-general","category-meter-display-technology","category-meter-duplexers","category-meteringtechnology","category-modbusprotocol","category-pulse-signaling","category-rockwell-protocols","category-sensus-protocol","tag-ultrasonic-meters"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2625","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2625"}],"version-history":[{"count":55,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2625\/revisions"}],"predecessor-version":[{"id":3655,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2625\/revisions\/3655"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/2666"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2625"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2625"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2625"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}