{"id":2275,"date":"2022-01-26T01:54:47","date_gmt":"2022-01-26T07:54:47","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=2275"},"modified":"2022-10-16T17:42:33","modified_gmt":"2022-10-16T23:42:33","slug":"introducing-the-analog-pulse-kit-for-sensus-and-other-flow-meters","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=2275","title":{"rendered":"Introducing the &#8216;Analog Pulse Kit&#8217; \u2014 The Analog SCADA Interface for Sensus\u00ae and Many Other Flow Meters!"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<p>SCADAmetrics<sup>\u00ae<\/sup>&nbsp;is pleased to introduce the newest member of our DINstrumentation<strong>&#x2122;<\/strong>&nbsp;series \u2013&nbsp;<strong>The Analog Pulse Kit!<\/strong><\/p>\n\n\n\n<p>This new instrument is available in two different model variations: the <strong>Model APK<\/strong>, which mounts on standard industrial DIN-rail, and the <strong>Model APK.PLUS<\/strong>, which features an LCD display and is contained within its own NEMA-4X enclosure.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-style-default\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Square_001.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" data-id=\"2288\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Square_001.jpg\" alt=\"\" class=\"wp-image-2288\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Square_001.jpg 500w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Square_001-300x300.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Square_001-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><figcaption>Model APK.PLUS<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-style-default\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"850\" height=\"850\" data-id=\"2298\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01.jpg\" alt=\"\" class=\"wp-image-2298\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01.jpg 850w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01-300x300.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01-150x150.jpg 150w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Front_20deg_sq01-768x768.jpg 768w\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" \/><\/a><figcaption>Model APK<\/figcaption><\/figure>\n<figcaption class=\"blocks-gallery-caption\"><strong>New Analog SCADA Interfaces by SCADAmetrics \u2014  for Sensus\u00ae and Many Other Flow Meters!<\/strong><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<p>The <strong>Analog Pulse Kit<\/strong> utilizes the unconditioned raw pulse output from the flow meter to provide a <strong>4-20 milliamp (flow) output<\/strong>, a <strong>clean, dry-contact pulse (per volume) output<\/strong>, and a <strong>clean, dry-contact flow switch output!<\/strong> The flow switch output can be used, for example, to trigger ON\/OFF a chemical disinfection pump.<\/p>\n\n\n\n<p>Certain flow meters, such as the <strong>Sensus\u00ae OMNI&#x2122;-Series<\/strong>, feature an unconditioned digital pulse output signal. The SCADAmetrics<strong> Analog Pulse Kit<\/strong> was designed to expand upon this pulse signal to provide an efficient flow meter interface to SCADA, Telemetry, and Building Automation Systems.<\/p>\n\n\n\n<p>Furthermore, the <strong>Analog Pulse Kit<\/strong> was designed using SCADAmetrics\u2019 signature approach of providing users with the capability to easily set the instrument\u2019s meter-specific behavior while in-the-field, as opposed to only at the factory. All meter-specific customization is accomplished using 16 integrated DIP-switches, which are set according to our lookup table. The obvious benefits to our approach are accelerated project schedules and shortened lead-times.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01-1024x691.jpg\" alt=\"\" class=\"wp-image-2282\" width=\"644\" height=\"434\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01-1024x691.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01-300x202.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01-768x518.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_Breakout_01.jpg 1427w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><\/a><figcaption>Model APK.PLUS &#8211; Feature Illustration<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01-1024x533.jpg\" alt=\"\" class=\"wp-image-2281\" width=\"615\" height=\"320\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01-1024x533.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01-300x156.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01-768x400.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_Breakout_01.jpg 1494w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \/><\/a><figcaption>Model APK &#8211; Feature Illustration<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<p>For <strong>Sensus\u00ae OMNI&#x2122;<\/strong> and <strong>HET Propeller Meters<\/strong>, the <strong>Analog Pulse Kit<\/strong> provides the necessary 24VDC auxiliary power supply for these unique, 3-wire pulse-type meters.<\/p>\n\n\n\n<p>For flow meters whose pulse output signal is too short-duration (milliseconds) or too high-frequency (Hz) to be detected by certain low-pulse-bandwidth BMS systems, the <strong>Analog Pulse Kit<\/strong> provides a <strong>Pulse Extension feature<\/strong>, which lengthens short-duration pulses to 100 milliseconds; and the <strong>Analog Pulse Kit<\/strong> also provides a <strong>Low-Speed Pulse Output feature<\/strong>, which decreases the pulse output frequency (Hz) by a factor of 10.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_QuickStart_01-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_QuickStart_01-990x1024.jpg\" alt=\"\" class=\"wp-image-2283\" width=\"757\" height=\"782\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_QuickStart_01-990x1024.jpg 990w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_QuickStart_01-290x300.jpg 290w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_QuickStart_01-768x794.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_QuickStart_01-1486x1536.jpg 1486w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APKPLUS_QuickStart_01-1981x2048.jpg 1981w\" sizes=\"auto, (max-width: 757px) 100vw, 757px\" \/><\/a><figcaption>Example APK.PLUS Application: SCADA Analog Interface for Sensus Omni-Series Water Meter<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"524\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_QuickStart_01-1024x524.jpg\" alt=\"\" class=\"wp-image-2300\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_QuickStart_01-1024x524.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_QuickStart_01-300x153.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_QuickStart_01-768x393.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_QuickStart_01-1536x785.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2022\/01\/APK_QuickStart_01-2048x1047.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>Example APK Application: SCADA Interface for Sensus Omni-Series Water Meter<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-features\">Key Features \u2013<\/h2>\n\n\n\n<p>\u2022 4-20mA Flow-Proportional Output (3KV Isolation).<br>\u2022 Dry-Contact, Volume-Proportional Output (3.75KV Isolation).<br>\u2022 Dry-Contact Flow-Switch Output (3.75KV Isolation).<\/p>\n\n\n\n<p>\u2022 Compatible with Most Late-Model, Pulse-Type Flow Meters.<br>\u2022 Works with All Popular Registration Units (Gallons, Cubic Feet, Cubic Meters, Acre Feet).<\/p>\n\n\n\n<p>\u2022 No Computer Required! \u2013 Setup via DIP Switches Only!<br>\u2022 Removable Terminal Blocks, Simplified Wiring Procedures.<br>\u2022 NEMA-4X Wall Mount, or Standard 35mm industrial DIN-rail-mount.<br>\u2022 24VDC-Powered (1.5KV Isolation). Low 1.2W Power Consumption.<br>\u2022 Enclosure and Circuit Board: UL 94-VO recognized materials.<br>\u2022 Simulation-Mode Feature: Emits 12mA and 1 Hz Pulse.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<p><strong><a href=\"https:\/\/www.scadametrics.com\/PDF\/APK_PLUS_01.pdf\">Download PDF Datasheet \/ User Manual Here: Model APK.PLUS &#8216;Analog Pulse Kit&#8217;<\/a><\/strong><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.scadametrics.com\/PDF\/APK_DIN_01.pdf\">Download PDF Datasheet \/ User Manual Here: Model APK &#8216;Analog Pulse Kit&#8217;<\/a><\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<p>Are you interested in learning how <strong>The Model APK or APK.PLUS Analog Pulse Kit<\/strong> can help you more closely monitor the flow through your water meters? Give us a call! We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SCADAmetrics\u00ae&nbsp;is pleased to introduce the newest member of our DINstrumentation&#x2122;&nbsp;series \u2013&nbsp;The Analog Pulse Kit! This new instrument is available in two different model variations: the Model APK, which mounts on standard industrial DIN-rail, and the Model APK.PLUS, which features an LCD display and is contained within its own NEMA-4X enclosure. The Analog Pulse Kit utilizes <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=2275\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":2288,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[262,3,8,250,4,263],"tags":[288,79,113,289,291,290],"class_list":["post-2275","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-4-20ma-flow-signaling","category-applications","category-general","category-meter-display-technology","category-meteringtechnology","category-pulse-signaling","tag-4-20milliamp","tag-act-pak-replacement","tag-flow-switch","tag-pulse-to-4-20milliamp-converter","tag-scada-interface-for-flow-meters","tag-scada-interface-for-water-meters"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2275","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2275"}],"version-history":[{"count":23,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2275\/revisions"}],"predecessor-version":[{"id":2467,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2275\/revisions\/2467"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/2288"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2275"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2275"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2275"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}