{"id":2192,"date":"2021-06-28T15:26:30","date_gmt":"2021-06-28T21:26:30","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=2192"},"modified":"2023-11-09T17:02:52","modified_gmt":"2023-11-09T23:02:52","slug":"add-an-open-channel-flow-meter-to-your-amr-ami-system","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=2192","title":{"rendered":"Add an Open-Channel Flow Meter to Your AMR\/AMI System!"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<p>In the past, Automatic Meter Reading (AMR) Systems for municipal water were generally limited to collecting flow totalization from water meters that were natively outfitted with a Sensus\/Neptune protocol signal.<\/p>\n\n\n\n<p>Today, the SCADAmetrics <strong>Encodalizer\u2122<\/strong> is able to provide a Sensus\/Neptune protocol option to many flow meters that otherwise would be precluded from your AMR\/AMI system.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"434\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-1024x434.jpg\" alt=\"\" class=\"wp-image-2158\" style=\"width:415px;height:175px\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-1024x434.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-300x127.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-768x325.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-1536x650.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-2048x867.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">The Encodalizer\u2122. Model MBE.<\/figcaption><\/figure>\n\n\n\n<p>One potential example would be the addition of a Siemens HydroRanger 200 open-channel flow meter into an AMR system.  The HydroRanger 200 is typically used to monitor flows through open channel wet wells, flumes, and weirs; and its integral LCD display shows totalization (gal), as well as instantaneous flow rate rate (gpm).  Because the totalization is also available via Modbus\/RTU, it may be converted into Sensus\/Neptune protocols with a SCADAmetrics Encodalizer.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_02.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"841\" height=\"1024\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_02-841x1024.jpg\" alt=\"\" class=\"wp-image-2195\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_02-841x1024.jpg 841w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_02-247x300.jpg 247w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_02-768x935.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_02-1262x1536.jpg 1262w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_02-1683x2048.jpg 1683w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_02.jpg 1977w\" sizes=\"auto, (max-width: 841px) 100vw, 841px\" \/><\/a><figcaption class=\"wp-element-caption\">HydroRanger200 Open-Channel Flow Application Illustration.<\/figcaption><\/figure>\n\n\n\n<p>Because Modbus technology provides the Encodalizer with a direct digital connection to the HydroRanger&#8217;s internal memory registers, the Encodalizer is thereby able to provide the connected AMR\/AMI system with a Sensus\/Neptune-Protocol totalizer reading that is a perfect match to the reading displayed on the HydroRanger itself! \u2013 <strong><em>We call this Revenue Grade Accuracy!<\/em><\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_Wiring_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"538\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_Wiring_01-1024x538.jpg\" alt=\"\" class=\"wp-image-2201\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_Wiring_01-1024x538.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_Wiring_01-300x158.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_Wiring_01-768x403.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/06\/HydroRanger200_Wiring_01.jpg 1276w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">HydroRanger \/ Encodalizer Wiring. Important Note! \u2013 The DC-Powered Version of the HydroRanger 200 (shown) is Recommended!<\/figcaption><\/figure>\n\n\n\n<p><strong><a href=\"https:\/\/scadametrics.com\/PDF\/MBE_v1.pdf\">Download PDF Datasheet \/ User Manual Here: TheEncodalizer<strong>\u2122<\/strong><\/a><\/strong><\/p>\n\n\n\n<p>Are you interested in how SCADAmetrics <strong>Encodalizer<\/strong> technology can help connect your open-channel flow meters to your AMR\/AMI system? Give us a call! We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In the past, Automatic Meter Reading (AMR) Systems for municipal water were generally limited to collecting flow totalization from water meters that were natively outfitted with a Sensus\/Neptune protocol signal. Today, the SCADAmetrics Encodalizer\u2122 is able to provide a Sensus\/Neptune protocol option to many flow meters that otherwise would be precluded from your AMR\/AMI system. <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=2192\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":2199,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,8,4,5,284,283],"tags":[],"class_list":["post-2192","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-general","category-meteringtechnology","category-modbusprotocol","category-neptune-protocol","category-sensus-protocol"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2192","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2192"}],"version-history":[{"count":10,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2192\/revisions"}],"predecessor-version":[{"id":2768,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2192\/revisions\/2768"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/2199"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2192"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2192"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2192"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}