{"id":2155,"date":"2021-05-11T13:07:35","date_gmt":"2021-05-11T19:07:35","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=2155"},"modified":"2024-08-01T08:43:35","modified_gmt":"2024-08-01T14:43:35","slug":"introducing-the-encodalizer","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=2155","title":{"rendered":"Introducing the Modbus Encodalizer\u2122!"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n\n\n\n<p>SCADAmetrics<sup>\u00ae<\/sup> is pleased to introduce <strong>The Modbus Encodalizer\u2122<\/strong>! \u2013 The new AMR\/AMI signal generator for water meters that provides a Sensus-Protocol output to certain flow meters that otherwise do not offer that option!<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"434\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-1024x434.jpg\" alt=\"\" class=\"wp-image-2158\" style=\"width:538px;height:227px\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-1024x434.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-300x127.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-768x325.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-1536x650.jpg 1536w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_001-2048x867.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">The Encodalizer\u2122. Model MBE.<\/figcaption><\/figure>\n\n\n\n<p>For example, the <strong>Siemens FM Mag 6000 Magnetic Flow Meter<\/strong> is outfitted with a <strong>4-20mA Rate Output<\/strong> (default), a <strong>Pulse Output<\/strong> (default) and <strong>Modbus\/RTU Signaling<\/strong> (optional) \u2013 but *not* Neptune or Sensus Encoder Protocol .  The Encodalizer taps into this meter&#8217;s Modbus\/RTU signal to create a <strong>Neptune or Sensus Protocol Output<\/strong>, thereby enabling this meter to be connected to a water utility&#8217;s AMR\/AMI system!<\/p>\n\n\n\n<p>Because Modbus technology provides the Encodalizer with a direct digital connection to the flow meter&#8217;s internal memory registers, the Encodalizer is thereby able to provide the connected AMR\/AMI system with a Sensus-Protocol totalizer reading that is a perfect match to the reading displayed on the physical meter itself! \u2013 <strong><em>We call this Revenue Grade Accuracy!<\/em><\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Concept_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"791\" height=\"558\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Concept_01.jpg\" alt=\"\" class=\"wp-image-2161\" style=\"width:563px;height:397px\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Concept_01.jpg 791w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Concept_01-300x212.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Concept_01-768x542.jpg 768w\" sizes=\"auto, (max-width: 791px) 100vw, 791px\" \/><\/a><figcaption class=\"wp-element-caption\">Encodalizer &#8211; Functional Illustration<\/figcaption><\/figure>\n\n\n\n<p>The Encodalizer was envisioned to serve as a <strong><em>&#8220;to-Encoder Protocol (Neptune or Sensus) Translator&#8221;<\/em><\/strong>, which would support a multitude of Modbus-enabled flow meters.  Presently, it supports the following meters:<\/p>\n\n\n<ul>\n<li>Endress-Hauser Promag W 400<\/li>\n<li>Flowtronic Torpee Magnetic Insertion Meter with TMC-20 Transmitter<\/li>\n<li>SCADAmetrics EM-100 EtherMeter<\/li>\n<li>Siemens FM Mag Series with Mag 6000 Transmitter<\/li>\n<\/ul>\n\n\n<p>The following is a list of meters for which we plan to add support in the near future:<\/p>\n\n\n<ul>\n<li>ABB AquaMaster, WaterMaster<\/li>\n<li>Rosemount 8750<\/li>\n<li>Seametrics Ag3000<\/li>\n<li>Krohne WaterFlux<\/li>\n<li>Toshiba MountAnywhere<\/li>\n<li>Foxboro 9500A Tube with IMT3xA Transmitter<\/li>\n<li>Sparling TigerMag<\/li>\n<\/ul>\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Exploded_View_01.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"565\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Exploded_View_01-1024x565.jpg\" alt=\"\" class=\"wp-image-2162\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Exploded_View_01-1024x565.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Exploded_View_01-300x166.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Exploded_View_01-768x424.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Encodalizer_Exploded_View_01.jpg 1227w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">The Encodalizer &#8211; Physical Breakout.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Feature Highlights \u2013<\/strong><\/h2>\n\n\n\n<p class=\"has-small-font-size\"> \u2022 RS-485 Modbus\/RTU Port with 2.5KV Isolation<br> \u2022 3-Wire Encoder Port with 2.5KV Isolation<br> \u2022 User-Settings via Dip Switches \u2013 No Computer Programming Required!<br> \u2022 User-Selectable Encoder Protocol: Neptune ECODER, Neptune PROREAD, Sensus 6,7,8,9<br> \u2022 User-Selectable Number of AMR Digits<br> \u2022 User-Selectable AMR Registration Units<br> \u2022 User-Selectable AMR Resolution<br> \u2022 Power: Accepts Wide Voltage Range: 8-28VDC<br> \u2022 Angled Terminal Blocks for Easy Wiring<br> \u2022 \u00bd\u201d NPT Male Threaded Fitting Adapts to Most MagMeter Transmitters<br> \u2022 Enclosure and Circuit Board: UL 94-VO recognized materials<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Siemens_6000_Encodalizer_02.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"782\" height=\"673\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Siemens_6000_Encodalizer_02.jpg\" alt=\"\" class=\"wp-image-2182\" style=\"width:626px;height:538px\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Siemens_6000_Encodalizer_02.jpg 782w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Siemens_6000_Encodalizer_02-300x258.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2021\/05\/Siemens_6000_Encodalizer_02-768x661.jpg 768w\" sizes=\"auto, (max-width: 782px) 100vw, 782px\" \/><\/a><figcaption class=\"wp-element-caption\">Model MBE &#8216;Encodalizer&#8217; &#8211; Attached to Siemens FM Mag 6000 Transmitter.<br>Transmitter Courtesy of Siemens Industry (Harleysville, PA).<br>Encodalizer Cover Removed to Illustrate Wiring and Dip Switches.<\/figcaption><\/figure>\n\n\n\n<p><strong><a href=\"https:\/\/scadametrics.com\/PDF\/MBE_v1.pdf\">Download PDF Datasheet \/ User Manual Here: TheEncodalizer<strong>\u2122<\/strong><\/a><\/strong><\/p>\n\n\n\n<p>Are you interested in how SCADAmetrics <strong>Encodalizer<\/strong> technology can help connect specialty process flow meters to your AMR\/AMI system? Give us a call! We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SCADAmetrics\u00ae is pleased to introduce The Modbus Encodalizer\u2122! \u2013 The new AMR\/AMI signal generator for water meters that provides a Sensus-Protocol output to certain flow meters that otherwise do not offer that option! For example, the Siemens FM Mag 6000 Magnetic Flow Meter is outfitted with a 4-20mA Rate Output (default), a Pulse Output (default) <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=2155\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":2176,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4,5],"tags":[207,120,281,159,160,41,16],"class_list":["post-2155","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-meteringtechnology","category-modbusprotocol","tag-ami","tag-amr","tag-encodalizer","tag-magmeter","tag-magnetic-flow-meter","tag-modbus","tag-sensus-protocol"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2155","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2155"}],"version-history":[{"count":34,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2155\/revisions"}],"predecessor-version":[{"id":3180,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/2155\/revisions\/3180"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/2176"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2155"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2155"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2155"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}