{"id":1597,"date":"2019-07-05T22:25:48","date_gmt":"2019-07-06T04:25:48","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=1597"},"modified":"2022-10-15T15:56:40","modified_gmt":"2022-10-15T21:56:40","slug":"a-meter-sharing-system-for-regional-water-utilities","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=1597","title":{"rendered":"A Meter Sharing System For Metropolitan &#038; Regional Water Utilities"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n<p>Regional Water Utilities deliver and sell wholesale water to their Satellite Districts through networks of distribution mains and custody transfer meters.\u00a0 The consumption data from these custody transfer meters \u2014 the &#8220;cash registers&#8221;, so to speak \u2014 are of vital interest to both parties; and regulations generally require that their readings be collected <span style=\"text-decoration: underline;\"><strong>daily<\/strong><\/span> \u2014 by both the seller <strong><span style=\"text-decoration: underline;\">and<\/span><\/strong> the buyer.<\/p>\n<p>Unfortunately, most modern encoder-output water meters are designed for connection to <strong><span style=\"text-decoration: underline;\">only one<\/span><\/strong> AMI\/AMR endpoint, which means that either the buyer or the seller (usually the buyer) will have to resort to climbing down into the meter vault to perform a daily &#8220;eyeball&#8221; meter read.\u00a0 In-vault meter reads are more prone to human error, pose a safety hazard for meter reader personnel (OSHA confined spaces), and consume more time.<\/p>\n<p>Today, with SCADAmetrics&#8217; introduction of its patent-pending <strong><a href=\"http:\/\/www.scadametrics.com\/PDF\/UDA_v811.pdf\">Universal Duplexer<\/a><\/strong>, custody transfer water meters may now be <span style=\"text-decoration: underline;\"><strong>shared<\/strong><\/span>, so that both the seller and buyer can connect their respective AMI\/AMR endpoints to the meter! \u2014 thereby obviating the need for either entity to perform daily &#8220;eyeball&#8221; reads of the utility&#8217;s most important meters!<\/p>\n<hr \/>\n<div id=\"attachment_1571\" style=\"width: 729px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/06\/UDA_Illustrated_01.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1571\" class=\"size-full wp-image-1571\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/06\/UDA_Illustrated_01.jpg\" alt=\"\" width=\"719\" height=\"465\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/06\/UDA_Illustrated_01.jpg 719w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/06\/UDA_Illustrated_01-300x194.jpg 300w\" sizes=\"auto, (max-width: 719px) 100vw, 719px\" \/><\/a><p id=\"caption-attachment-1571\" class=\"wp-caption-text\">Universal Duplexer Allows Two (or More) AMI\/AMR Endpoints to Be Connected to a Single Water Meter.<\/p><\/div>\n<p>\u00a0<\/p>\n<hr \/>\n<h2><span style=\"text-decoration: underline;\"><strong>Illustrated Solution (click to zoom):<\/strong><\/span><\/h2>\n<div id=\"attachment_1627\" style=\"width: 590px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/07\/Regional_Meter_Sharing_01-1.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1627\" class=\"size-large wp-image-1627\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/07\/Regional_Meter_Sharing_01-1-637x1024.jpg\" alt=\"\" width=\"580\" height=\"932\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/07\/Regional_Meter_Sharing_01-1-637x1024.jpg 637w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/07\/Regional_Meter_Sharing_01-1-187x300.jpg 187w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/07\/Regional_Meter_Sharing_01-1-768x1235.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/07\/Regional_Meter_Sharing_01-1.jpg 1060w\" sizes=\"auto, (max-width: 580px) 100vw, 580px\" \/><\/a><p id=\"caption-attachment-1627\" class=\"wp-caption-text\">Meter Sharing System for Metropolitan and Regional Water Utilities.<\/p><\/div>\n<hr \/>\n<p>It is important to note that the <strong>Universal Duplexer<\/strong> is truly <em><strong>&#8220;<span style=\"text-decoration: underline;\">universal<\/span>&#8220;:<\/strong><\/em> It enables the splitting of signals <strong><span style=\"text-decoration: underline;\">from<\/span><\/strong> every major encoder-type water meter <strong><span style=\"text-decoration: underline;\">to<\/span><\/strong> every major AMI\/AMR\/Visual endpoint in the industry \u2014 including those from <strong>Sensus<\/strong>, <strong>Neptune<\/strong>, <strong>Metron-Farnier<\/strong>, <strong>Kemp-Meek<\/strong>, <strong>Aclara<\/strong>, <strong>Mueller<\/strong>, <strong>Kamstrup<\/strong>, <strong>Badger<\/strong>, <strong>Master Meter<\/strong>, <strong>RG3<\/strong>, <strong>Zenner<\/strong>, <strong>Itron<\/strong>, <strong>Elster-AMCO\/Honeywell<\/strong>, <strong>McCrometer<\/strong>, and many others!\u00a0 And universal compatibility is necessary, because Regional Water Utilities and their Satellite Wholesale Customers will generally present with an in-homogeneous set of AMI\/AMR endpoints.<\/p>\n<hr \/>\n<p>Are you interested in how SCADAmetrics technology can <span style=\"text-decoration: underline;\"><strong>foster meter-reading harmony<\/strong><\/span> between Regional Water Utilities and their Satellite Wholesale Customers?\u00a0 Give us a call! We\u2019ll be glad to discuss the details!<\/p>\n<p>P.S. &#8211; Due to popular request, we have published this meter-sharing technique in a downloadable <strong>White Paper<\/strong> (PDF): <a href=\"https:\/\/scadametrics.com\/PDF\/Metropolitan_Meter_Sharing_01.pdf\"><strong>CLICK HERE<\/strong><\/a>.\u00a0 Please feel free to download and share with your colleagues!<\/p>\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Regional Water Utilities deliver and sell wholesale water to their Satellite Districts through networks of distribution mains and custody transfer meters.\u00a0 The consumption data from these custody transfer meters \u2014 the &#8220;cash registers&#8221;, so to speak \u2014 are of vital interest to both parties; and regulations generally require that their readings be collected daily \u2014 <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=1597\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":1618,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,8,205,4],"tags":[73,227,235,71],"class_list":["post-1597","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-general","category-meter-duplexers","category-meteringtechnology","tag-custody-transfer-meter","tag-meter-sharing","tag-regional-water-utility","tag-water-meter-sharing"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1597"}],"version-history":[{"count":1,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1597\/revisions"}],"predecessor-version":[{"id":2401,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1597\/revisions\/2401"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/1618"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1597"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1597"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}