{"id":1514,"date":"2019-05-10T10:25:22","date_gmt":"2019-05-10T16:25:22","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=1514"},"modified":"2022-10-15T15:57:07","modified_gmt":"2022-10-15T21:57:07","slug":"coming-soon-new-amr-signal-splitter-for-scada-applications","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=1514","title":{"rendered":"Introducing the AMI Duplexer for SCADA Systems!"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n<p>You have an AMI-capable water meter, and you are quite satisfied with its ability to transmit revenue-grade readings into your AMI system \u2013 but in certain situations, wouldn\u2019t it be useful if you could collect those same revenue-grade readings into your SCADA system, as well?<\/p>\n<p>The <a href=\"http:\/\/www.scadametrics.com\/products\/products.htm#SDA\"><strong>Model SDA \u201cAMI Duplexer for SCADA Systems\u201d<\/strong><\/a> was designed for that exact purpose!<\/p>\n<div id=\"attachment_1515\" style=\"width: 422px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_001s.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1515\" class=\"wp-image-1515\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_001s.jpg\" alt=\"\" width=\"412\" height=\"400\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_001s.jpg 771w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_001s-300x291.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_001s-768x745.jpg 768w\" sizes=\"auto, (max-width: 412px) 100vw, 412px\" \/><\/a><p id=\"caption-attachment-1515\" class=\"wp-caption-text\">Model SDA, &#8220;AMI Duplexer, SCADA-Version&#8221;<\/p><\/div>\n<p>The <strong>AMI Duplexer for SCADA Systems<\/strong> enables the splitting of AMI signals from every major AMI-capable water meter to every major AMI\/AMR\/Visual endpoint in the industry \u2013 including those from <strong>Sensus<\/strong>, <strong>Neptune<\/strong>, <strong>Metron-Farnier<\/strong>, <strong>Kemp-Meek<\/strong>, <strong>Aclara<\/strong>, <strong>Mueller<\/strong>, <strong>Kamstrup<\/strong>, <strong>Badger<\/strong>, <strong>Master Meter<\/strong>, <strong>RG3<\/strong>, <strong>Zenner<\/strong>, <strong>Itron<\/strong>, <strong>Elster-AMCO<\/strong>, <strong>McCrometer<\/strong>, and many others!<\/p>\n<div id=\"attachment_1573\" style=\"width: 752px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_Illustrated_01.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1573\" class=\"size-full wp-image-1573\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_Illustrated_01.jpg\" alt=\"\" width=\"742\" height=\"488\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_Illustrated_01.jpg 742w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_Illustrated_01-300x197.jpg 300w\" sizes=\"auto, (max-width: 742px) 100vw, 742px\" \/><\/a><p id=\"caption-attachment-1573\" class=\"wp-caption-text\">SCADA Duplexer &#8211; Conceptual Illustration<\/p><\/div>\n<p>The AMI Duplexer maintains all the popular functionality contained within our retired <strong>Radio-Read Filter<\/strong> device which led to its widespread acceptance at major water utilities throughout the United States and Canada \u2013 PLUS the additions of an attractive, compact din-rail case and a convenient removable terminal block.<\/p>\n<p>It is important to note that the SDA \u201cAMI Duplexer for SCADA Systems\u201d is designed to <span style=\"text-decoration: underline;\"><strong>only<\/strong><\/span> split a meter signal to a <a href=\"http:\/\/www.scadametrics.com\/products\/products.htm#EM100\"><strong>SCADAmetrics EtherMeter<\/strong><\/a> plus a third-party AMI device.\u00a0 If signal splitting to strictly non-EtherMeter devices is desired, then the UDA \u201cUniversal Duplexer for AMI\u201d is the recommended signal splitter.<\/p>\n<h2>Sample Application:<\/h2>\n<div id=\"attachment_1594\" style=\"width: 890px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_Badger.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1594\" class=\"size-full wp-image-1594\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_Badger.jpg\" alt=\"\" width=\"880\" height=\"512\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_Badger.jpg 880w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_Badger-300x175.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2019\/05\/SDA_Badger-768x447.jpg 768w\" sizes=\"auto, (max-width: 880px) 100vw, 880px\" \/><\/a><p id=\"caption-attachment-1594\" class=\"wp-caption-text\">SCADA Duplexer Splitting Metering Data between Badger Orion AMI System and a SCADA System.<\/p><\/div>\n<hr \/>\n<p>Are you interested in how SCADAmetrics technology can help you to eliminate pulse-counting errors and split a water meter\u2019s encoder signal to both your AMI and SCADA systems? Give us a call! We\u2019ll be glad to discuss the details!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>You have an AMI-capable water meter, and you are quite satisfied with its ability to transmit revenue-grade readings into your AMI system \u2013 but in certain situations, wouldn\u2019t it be useful if you could collect those same revenue-grade readings into your SCADA system, as well? The Model SDA \u201cAMI Duplexer for SCADA Systems\u201d was designed <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=1514\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":1520,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,8,205,4],"tags":[60,136,236,237,238,71],"class_list":["post-1514","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-general","category-meter-duplexers","category-meteringtechnology","tag-absolute-encoder","tag-meter-data-sharing","tag-scada-systems","tag-signal-duplexer","tag-signal-splitter","tag-water-meter-sharing"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1514","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1514"}],"version-history":[{"count":1,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1514\/revisions"}],"predecessor-version":[{"id":2403,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1514\/revisions\/2403"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/1520"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1514"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1514"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1514"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}