{"id":1353,"date":"2018-01-27T20:14:21","date_gmt":"2018-01-28T02:14:21","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=1353"},"modified":"2022-10-15T15:58:45","modified_gmt":"2022-10-15T21:58:45","slug":"mccrometer-ultramag-commissioning-for-use-with-the-ethermeter","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=1353","title":{"rendered":"McCrometer UltraMag Commissioning for Use with the EtherMeter"},"content":{"rendered":"<div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>\n<p>The <strong>UltraMag<\/strong>, by <a href=\"http:\/\/mccrometer.com\"><strong>McCrometer (Hemet, CA)<\/strong><\/a>, is an excellent Magnetic Flowmeter for water and wastewater applications; and this article illustrates the installation and commissioning of a 3 inch UltraMag, which is then tied into the host SCADA System through a <strong>SCADAmetrics EtherMeter<sup>\u00ae<\/sup><\/strong>\u00a0using the <strong>Modbus\/RTU<\/strong> (RS-485) protocol.<\/p>\n<p>The venue is a custody-transfer valve &amp; metering station, where a large regional water district sells water to a rural municipality.\u00a0 The station&#8217;s meter readings and flow-rates are continuously tracked for the purposes of both <strong>operations monitorin<\/strong>g and <strong>billing;<\/strong>\u00a0and therefore SCADA readings that match the transmitter readings are absolutely required\u00a0\u2014 often referred to as\u00a0<em><strong>revenue-grade accuracy<\/strong><\/em>.<\/p>\n<p>A legacy turbine-based flow meter at this site had required replacement several times due to mechanical parts wear; and thus the installation of this <strong>100% solid-state flow meter<\/strong> was intended to alleviate such problems in the future.<\/p>\n<div id=\"attachment_1383\" style=\"width: 590px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/farina_01.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1383\" class=\"wp-image-1383 size-large\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/farina_01-1024x582.jpg\" alt=\"\" width=\"580\" height=\"330\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/farina_01-1024x582.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/farina_01-300x170.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/farina_01-768x436.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/farina_01.jpg 1384w\" sizes=\"auto, (max-width: 580px) 100vw, 580px\" \/><\/a><p id=\"caption-attachment-1383\" class=\"wp-caption-text\">SCADA-Monitored Valve and Master Meter Station.<\/p><\/div>\n<p>It is important to note that when the UltraMag is equipped with the <em><strong>&#8220;SmartOutput&#8221;<\/strong><\/em>\u00a0option, then it becomes an AMR\/AMI-compatible flow meter, and thus can communicate its <strong>Totalizer<\/strong> and <strong>Flow-Rate<\/strong> to an EtherMeter-equipped SCADA System or AMR System with <em><strong>Revenue-Grade Accuracy<\/strong><\/em>.<\/p>\n<div id=\"attachment_1358\" style=\"width: 766px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/00_roughed_in.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1358\" class=\"wp-image-1358 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/00_roughed_in.jpg\" alt=\"\" width=\"756\" height=\"1008\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/00_roughed_in.jpg 756w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/00_roughed_in-225x300.jpg 225w\" sizes=\"auto, (max-width: 756px) 100vw, 756px\" \/><\/a><p id=\"caption-attachment-1358\" class=\"wp-caption-text\">The Flow Meter is Mechanically-Installed, But Not Yet Powered-Up or Commissioned. Note that on both the Upstream and Downstream Sides, a Grounding Ring is Installed (each is Sandwiched Between a pair of Full-Flange Rubber Gaskets). McCrometer Packages Two (2) Stainless Steel Grounding Rings with each (Flanged-Version) UltraMag Flow Meter.<\/p><\/div>\n<div id=\"attachment_1359\" style=\"width: 1018px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/01_remove_backcover.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1359\" class=\"wp-image-1359 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/01_remove_backcover.jpg\" alt=\"\" width=\"1008\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/01_remove_backcover.jpg 1008w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/01_remove_backcover-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/01_remove_backcover-768x576.jpg 768w\" sizes=\"auto, (max-width: 1008px) 100vw, 1008px\" \/><\/a><p id=\"caption-attachment-1359\" class=\"wp-caption-text\">The Back Cover is Removed, Using an M5 Hex Allen Wrench.<\/p><\/div>\n<div id=\"attachment_1360\" style=\"width: 1018px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/02_power_signal.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1360\" class=\"wp-image-1360 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/02_power_signal.jpg\" alt=\"\" width=\"1008\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/02_power_signal.jpg 1008w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/02_power_signal-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/02_power_signal-768x576.jpg 768w\" sizes=\"auto, (max-width: 1008px) 100vw, 1008px\" \/><\/a><p id=\"caption-attachment-1360\" class=\"wp-caption-text\">The provided Itron SmartOutput Cable was removed, as our personal preference is to use a single cable for both SmartOutput and Remote DC Power Input.\u00a0 The Power and SmartOutput Phoenix Headers are Removed, and the Appropriate Wires Are Landed. In this case, we are using General Cable C0764A 8-Conductor, Shielded Cable. Smart Output: RED:Meter.Tx, GRN:Meter.Rx, BLK:Meter.CMN. Power: RED\/BLK:+24VDC, WHT\/BLK:DC CMN, BLU:GND. The DRAIN wire and unused conductors (ORG and WHT) were bonded to Chassis Ground in the SCADA Panel, and Clipped in the Meter Transmitter. Note that McCrometer offers a signal that they call &#8220;SmartOutput&#8221;. This signal is essentially &#8220;Sensus Protocol&#8221;, and is offered in 6, 8, and 9-digit versions. 9-digits is SCADAmetrics&#8217; preferred configuration.\u00a0 If the SmartOutput must be co-connected to an AMR system, then it is recommended that the user check which configuration is compatible (6, 8, or 9 digits).<\/p><\/div>\n<div id=\"attachment_1361\" style=\"width: 766px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/03_power_signal_landed.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1361\" class=\"wp-image-1361 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/03_power_signal_landed.jpg\" alt=\"\" width=\"756\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/03_power_signal_landed.jpg 756w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/03_power_signal_landed-150x150.jpg 150w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/03_power_signal_landed-300x300.jpg 300w\" sizes=\"auto, (max-width: 756px) 100vw, 756px\" \/><\/a><p id=\"caption-attachment-1361\" class=\"wp-caption-text\">Re-Insert Phoenix Headers for Power and Smart Output Signaling; and Seal the Back Cover Using an M5 Hex Allen Wrench. Note that the Original Itron Cable is Replaced with Our 8-Conductor General Cable C0764A, which is carrying both DC Power and SmartOutput signaling.<\/p><\/div>\n<div id=\"attachment_1362\" style=\"width: 766px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/04_unbundle_gnd_jumpers.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1362\" class=\"wp-image-1362 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/04_unbundle_gnd_jumpers.jpg\" alt=\"\" width=\"756\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/04_unbundle_gnd_jumpers.jpg 756w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/04_unbundle_gnd_jumpers-150x150.jpg 150w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/04_unbundle_gnd_jumpers-300x300.jpg 300w\" sizes=\"auto, (max-width: 756px) 100vw, 756px\" \/><\/a><p id=\"caption-attachment-1362\" class=\"wp-caption-text\">Un-Bundle the Pre-Connected Convenience Grounding Wires.<\/p><\/div>\n<div id=\"attachment_1363\" style=\"width: 1018px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/05_gnd_completed.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1363\" class=\"wp-image-1363 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/05_gnd_completed.jpg\" alt=\"\" width=\"1008\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/05_gnd_completed.jpg 1008w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/05_gnd_completed-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/05_gnd_completed-768x576.jpg 768w\" sizes=\"auto, (max-width: 1008px) 100vw, 1008px\" \/><\/a><p id=\"caption-attachment-1363\" class=\"wp-caption-text\">Connect One Convenience Grounding Wire to the Upstream Grounding Ring, and Connect the Other Convenience Grounding Wire to the Downstream Grounding Ring. Add a Mechanical Grounding Lug for External Ground Connection at one of the Grounding Rings (e.g. Burndy Part No. KA8CBAG2R).<\/p><\/div>\n<div id=\"attachment_1364\" style=\"width: 1018px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/06_amr_setup.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1364\" class=\"wp-image-1364 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/06_amr_setup.jpg\" alt=\"\" width=\"1008\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/06_amr_setup.jpg 1008w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/06_amr_setup-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/06_amr_setup-768x576.jpg 768w\" sizes=\"auto, (max-width: 1008px) 100vw, 1008px\" \/><\/a><p id=\"caption-attachment-1364\" class=\"wp-caption-text\">The UktraMag should be configured using the LCD display and keypad of its transmitter. In order to access the User Menu, the access code should be entered: 000002 for M-series transmitters (blue) or 40000000 for ProComm-series transmitters (white). Then, using the Integral Keypad and LCD Display, Set the Measurement Units (Tot.MU) to GAL 00001. GAL sets the Meter to Gallons, and 00001 sets the Smart Output to Single-Gallon Resolution. The Pulse Output Parameters Were Not Modified, As the EtherMeter is Only Using the SmartOutput, and Not Using the Pulse In This Case. Resolution should be set based on meter size. For 1&#8243; meters and below, 0.1 Gallon Resolution is Recommended. For 1.5&#8243;, 2&#8243;, and 3&#8243; meters, 1 Gallon Resolution is Recommended. For 4&#8243; and above, 10 Gallon Resolution is Recommended.<\/p><\/div>\n<div id=\"attachment_1369\" style=\"width: 1018px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/11_meter_final.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1369\" class=\"wp-image-1369 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/11_meter_final.jpg\" alt=\"\" width=\"1008\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/11_meter_final.jpg 1008w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/11_meter_final-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/11_meter_final-768x576.jpg 768w\" sizes=\"auto, (max-width: 1008px) 100vw, 1008px\" \/><\/a><p id=\"caption-attachment-1369\" class=\"wp-caption-text\">The Completed and Fully-Commissioned Installation.<\/p><\/div>\n<div id=\"attachment_1370\" style=\"width: 1018px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/09_ctrl_panel_inner.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1370\" class=\"wp-image-1370 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/09_ctrl_panel_inner.jpg\" alt=\"\" width=\"1008\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/09_ctrl_panel_inner.jpg 1008w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/09_ctrl_panel_inner-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/09_ctrl_panel_inner-768x576.jpg 768w\" sizes=\"auto, (max-width: 1008px) 100vw, 1008px\" \/><\/a><p id=\"caption-attachment-1370\" class=\"wp-caption-text\">A View of the SCADA Control Panel &#8211; Internal View. Note the SCADAmetrics EtherMeter in the Lower Left, Partially Hidden by the UPS Battery Backup.<\/p><\/div>\n<div id=\"attachment_1368\" style=\"width: 1018px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/10_ctrl_panel_outer.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1368\" class=\"wp-image-1368\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/10_ctrl_panel_outer-1024x768.jpg\" alt=\"\" width=\"1008\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/10_ctrl_panel_outer-1024x768.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/10_ctrl_panel_outer-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/10_ctrl_panel_outer-768x576.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/10_ctrl_panel_outer.jpg 2016w\" sizes=\"auto, (max-width: 1008px) 100vw, 1008px\" \/><\/a><p id=\"caption-attachment-1368\" class=\"wp-caption-text\">A View of the SCADA Panel &#8211; External View.<\/p><\/div>\n<div id=\"attachment_1365\" style=\"width: 1018px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/07_em_total.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1365\" class=\"wp-image-1365 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/07_em_total.jpg\" alt=\"\" width=\"1008\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/07_em_total.jpg 1008w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/07_em_total-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/07_em_total-768x576.jpg 768w\" sizes=\"auto, (max-width: 1008px) 100vw, 1008px\" \/><\/a><p id=\"caption-attachment-1365\" class=\"wp-caption-text\">The Connected EtherMeter displaying the Totalization, which is an exact match to the reading on the McCrometer Transmitter. This reading is collected using the SmartOutput signal.<\/p><\/div>\n<div id=\"attachment_1366\" style=\"width: 1018px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/08_em_flow.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1366\" class=\"wp-image-1366 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/08_em_flow.jpg\" alt=\"\" width=\"1008\" height=\"756\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/08_em_flow.jpg 1008w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/08_em_flow-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/08_em_flow-768x576.jpg 768w\" sizes=\"auto, (max-width: 1008px) 100vw, 1008px\" \/><\/a><p id=\"caption-attachment-1366\" class=\"wp-caption-text\">The Connected EtherMeter displaying Flow Rate. This quantity is derived internally in the EtherMeter by calculating delta-Total\/delta-Time at periodic intervals.<\/p><\/div>\n<h3><span style=\"text-decoration: underline;\"><strong>Sample SCADA System Data:<\/strong><\/span><\/h3>\n<div id=\"attachment_1412\" style=\"width: 479px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_2_01_valve_open.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1412\" class=\"wp-image-1412 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_2_01_valve_open.png\" alt=\"\" width=\"469\" height=\"39\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_2_01_valve_open.png 469w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_2_01_valve_open-300x25.png 300w\" sizes=\"auto, (max-width: 469px) 100vw, 469px\" \/><\/a><p id=\"caption-attachment-1412\" class=\"wp-caption-text\">24-Hour History Chart: &#8220;Valve Open&#8221;<\/p><\/div>\n<div id=\"attachment_1413\" style=\"width: 479px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_3_00_flow.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1413\" class=\"wp-image-1413 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_3_00_flow.png\" alt=\"\" width=\"469\" height=\"95\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_3_00_flow.png 469w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_3_00_flow-300x61.png 300w\" sizes=\"auto, (max-width: 469px) 100vw, 469px\" \/><\/a><p id=\"caption-attachment-1413\" class=\"wp-caption-text\">24-Hour History Chart: &#8220;Rate-of-Flow&#8221; Gallons per Minute (above)<\/p><\/div>\n<div id=\"attachment_1414\" style=\"width: 479px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_4_00_meter.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1414\" class=\"wp-image-1414 size-full\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_4_00_meter.png\" alt=\"\" width=\"469\" height=\"95\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_4_00_meter.png 469w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2018\/01\/h_2018_02_08_024_4_00_meter-300x61.png 300w\" sizes=\"auto, (max-width: 469px) 100vw, 469px\" \/><\/a><p id=\"caption-attachment-1414\" class=\"wp-caption-text\">24-Hour History Chart: &#8220;Meter Reading&#8221; Gallons (above)<\/p><\/div>\n<p>Do you have an application where you would like to connect your flow meter to a SCADA system?\u00a0 The McCrometer UltraMag flow meter (flanged and insertion models) and McCrometer Propeller flow meters offer industry-standard signal outputs that allow the EtherMeter to tie these meters into Modbus- and Rockwell (Allen Bradley)-based SCADA systems via Ethernet, RS-485, or RS-232 signaling.\u00a0 Give us a call\u2026 We\u2019ll be glad to discuss your application in detail.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The UltraMag, by McCrometer (Hemet, CA), is an excellent Magnetic Flowmeter for water and wastewater applications; and this article illustrates the installation and commissioning of a 3 inch UltraMag, which is then tied into the host SCADA System through a SCADAmetrics EtherMeter\u00ae\u00a0using the Modbus\/RTU (RS-485) protocol. The venue is a custody-transfer valve &amp; metering station, <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=1353\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":1372,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,8,4,5,6,10],"tags":[159,160,163,191,164],"class_list":["post-1353","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-general","category-meteringtechnology","category-modbusprotocol","category-rockwell-protocols","category-satellite-communications","tag-magmeter","tag-magnetic-flow-meter","tag-mccrometer","tag-smartoutput","tag-ultramag"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1353","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1353"}],"version-history":[{"count":43,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1353\/revisions"}],"predecessor-version":[{"id":2409,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1353\/revisions\/2409"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/1372"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1353"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1353"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1353"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}