{"id":1109,"date":"2016-12-11T21:55:05","date_gmt":"2016-12-12T03:55:05","guid":{"rendered":"https:\/\/scadametrics.com\/blog\/?p=1109"},"modified":"2022-10-15T16:01:37","modified_gmt":"2022-10-15T22:01:37","slug":"bell-202-modem-compatible-with-ritron-dtx-series-telemetry-radio","status":"publish","type":"post","link":"https:\/\/scadametrics.com\/blog\/?p=1109","title":{"rendered":"Bell 202 Modem Compatible with Ritron DTX+ Series Telemetry Radio"},"content":{"rendered":"<p><div id=\"attachment_3732\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3732\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1-150x150.jpeg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2025\/07\/IMG_0987-1.jpeg 2x\" alt=\"James Mimlitz &#039;Slim&#039;\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-3732\" class=\"wp-caption-text\">Jim &#8216;Slim&#8217; Mimlitz, SCADAmetrics<\/p><\/div>In 2012, SCADAmetrics introduced the <strong><a href=\"http:\/\/www.scadametrics.com\/PDF\/B202v103.pdf\" target=\"_blank\" rel=\"noopener\">B202<\/a><\/strong> \u2014 an <strong>Industrial Bell 202 Modem<\/strong> designed for <strong>Radio Telemetry Applications<\/strong>. The B202 is designed to provide external, non-proprietary data modulation\/demodulation for a wide range of popular narrowband analog telemetry radios, including models from Ritron, Tecnet\/Maxon, GE\/MDS, RF Neulink, and Calamp.<\/p>\n<div id=\"attachment_860\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/09\/Bell-202-001.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-860\" class=\"size-medium wp-image-860\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/09\/Bell-202-001-300x232.jpg\" alt=\"B202: SCADAmetrics Bell-202 Modem for Telemetry Radios.\" width=\"300\" height=\"232\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/09\/Bell-202-001-300x232.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2015\/09\/Bell-202-001.jpg 323w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-860\" class=\"wp-caption-text\">B202: SCADAmetrics Bell-202 Modem for Telemetry Radios.<\/p><\/div>\n<p>We recently performed extensive laboratory and field validation of compatibility between the narrow-band <a href=\"http:\/\/www.scadametrics.com\/PDF\/DTXPLUS_Din_Rail_001.pdf\">DTX+ Series Telemetry Radio<\/a>, manufactured by <a href=\"http:\/\/ritron.com\">Ritron Wireless Solutions<\/a> and the B202.<\/p>\n<div id=\"attachment_1114\" style=\"width: 342px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/DTX_Plus_Radio_with_Bracket.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1114\" class=\" wp-image-1114\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/DTX_Plus_Radio_with_Bracket-1024x837.jpg\" alt=\"\" width=\"332\" height=\"272\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/DTX_Plus_Radio_with_Bracket-1024x837.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/DTX_Plus_Radio_with_Bracket-300x245.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/DTX_Plus_Radio_with_Bracket-768x628.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/DTX_Plus_Radio_with_Bracket.jpg 1592w\" sizes=\"auto, (max-width: 332px) 100vw, 332px\" \/><\/a><p id=\"caption-attachment-1114\" class=\"wp-caption-text\">Ritron DTX+ Telemetry Radio with SCADAmetrics Industrial Din-Rail Mounting Kit<\/p><\/div>\n<p>As a result of our tests, we are pleased to report that compatibility was verified. Also, we have authored an Application Note that details the steps required to use the B202 with the Ritron DTX+: <strong><a href=\"http:\/\/www.scadametrics.com\/PDF\/App_Note_M005.pdf\" target=\"_blank\" rel=\"noopener\">Link to Application Note<\/a><\/strong><\/p>\n<p>Furthermore, in an\u00a0effort to increase\u00a0installation and maintenance convenience for SCADA and Telemetry applications, SCADAmetrics has developed a DTX+ mounting kit for 35mm industrial din rail.<\/p>\n<p>The DTX+ is a truly excellent telemetry radio module. \u00a0It is manufactured in the USA, and is available in the following frequency bands: 136-174MHz, 217-245MHz, 380-400MHz, 400-430MHz, and 450-470MHz.<\/p>\n<p>Are you interested in utilizing the Ritron DTX+ and the SCADAmetrics B202 Modem in a SCADA\/Telemetry application? \u00a0Give us a call, and we&#8217;ll be glad to discuss your application in detail.<\/p>\n<div id=\"attachment_1133\" style=\"width: 590px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/Pump_Station_SCADA.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1133\" class=\"size-large wp-image-1133\" src=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/Pump_Station_SCADA-1024x768.jpg\" alt=\"\" width=\"580\" height=\"435\" srcset=\"https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/Pump_Station_SCADA-1024x768.jpg 1024w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/Pump_Station_SCADA-300x225.jpg 300w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/Pump_Station_SCADA-768x576.jpg 768w, https:\/\/scadametrics.com\/blog\/wp-content\/uploads\/2016\/12\/Pump_Station_SCADA.jpg 1280w\" sizes=\"auto, (max-width: 580px) 100vw, 580px\" \/><\/a><p id=\"caption-attachment-1133\" class=\"wp-caption-text\">Ritron DTX+ Telemetry Radio and SCADAmetrics B202 Modem Installed as Communication Hardware for a Pumping Station SCADA System.<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In 2012, SCADAmetrics introduced the B202 \u2014 an Industrial Bell 202 Modem designed for Radio Telemetry Applications. The B202 is designed to provide external, non-proprietary data modulation\/demodulation for a wide range of popular narrowband analog telemetry radios, including models from Ritron, Tecnet\/Maxon, GE\/MDS, RF Neulink, and Calamp. We recently performed extensive laboratory and field validation <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/scadametrics.com\/blog\/?p=1109\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":1114,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,125,8,5,6],"tags":[127,126,42,41,128],"class_list":["post-1109","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-bell-202-modem","category-general","category-modbusprotocol","category-rockwell-protocols","tag-bell-202","tag-bell-202-modem","tag-df1","tag-modbus","tag-modem"],"_links":{"self":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1109","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1109"}],"version-history":[{"count":22,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1109\/revisions"}],"predecessor-version":[{"id":2418,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1109\/revisions\/2418"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/1114"}],"wp:attachment":[{"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1109"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1109"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scadametrics.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1109"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}